Evidence of the behavior of the periodontal tissues around anterior teeth restored with the biologically oriented preparation technique (BOPT) is available. However, outcomes of this technique in posterior teeth restored with fixed partial dentures (FPDs) are lacking.
The purpose of this randomized controlled clinical trial was to evaluate the clinical, mechanical, and biological behavior of posterior 3-unit FPDs placed on teeth prepared with BOPT.
Forty participants received a 3-unit zirconia FPD in the posterior region of the mandible or maxilla. Twenty FPDs were placed on teeth prepared with BOPT (study group) and 20 on teeth with a horizontal chamfer finishing line (control group). Follow-up examinations were performed 1, 3, and 5 years after treatment to evaluate periodontal responses around the prepared teeth by means of the following parameters: plaque index, gingival index, probing depth, and marginal stability (MS). Mechanical behavior was also assessed, as were any complications.
After the 5-year follow-up, 57.9% of the control group and 35% of the BOPT group presented a plaque index of 1. The gingival index was 1 in 68.4% of the control group and 30% of the BOPT group after the follow-up period. In the analysis of probing depth, 26.3% of teeth in the control group had pockets of more than 3 mm in depth, whereas the BOPT group had only 10%. Marginal stability appeared in 100% of the BOPT group, whereas only 10.5% of the control group exhibited gingival stability. Complications during the follow-up period were similar, 20% in the control group and 15% in the BOPT group.
Posterior FPDs prepared by using BOPT had a good clinical response over a 5-year follow-up, with a low gingival index, a small increase in pocket depth, and a 100% marginal stability of the surrounding tissues. High survival rates after 5 years indicated that the technique produced predictable outcomes.
有证据表明,采用生物导向预备技术(BOPT)修复前牙的牙周组织行为。然而,在使用固定局部义齿(FPD)修复后牙方面,这种技术的结果尚不清楚。
本随机对照临床试验的目的是评估采用 BOPT 预备的后牙 3 单位 FPD 的临床、机械和生物学行为。
40 名参与者在下颌或上颌后牙区接受了 3 单位氧化锆 FPD。20 个 FPD 放置在采用 BOPT 预备的牙齿上(研究组),20 个放置在具有水平倒角收尾线的牙齿上(对照组)。治疗后 1、3 和 5 年进行随访检查,通过以下参数评估预备牙周围的牙周反应:菌斑指数、牙龈指数、探诊深度和边缘稳定性(MS)。还评估了机械行为以及任何并发症。
5 年随访后,对照组中有 57.9%,BOPT 组中有 35%的菌斑指数为 1。在随访期间,对照组中有 68.4%,BOPT 组中有 30%的牙龈指数为 1。在探诊深度分析中,对照组中有 26.3%的牙齿探诊深度超过 3mm,而 BOPT 组仅有 10%。BOPT 组边缘稳定性为 100%,而对照组仅有 10.5%。在随访期间,并发症相似,对照组为 20%,BOPT 组为 15%。
在 5 年的随访中,采用 BOPT 预备的后牙 FPD 具有良好的临床反应,牙龈指数低,探诊深度略有增加,周围组织的边缘稳定性为 100%。5 年后的高存活率表明该技术产生了可预测的结果。