Suppr超能文献

动态负载下具有新型银涂层的钛植入物的骨整合。

Osseointegration of titanium implants with a novel silver coating under dynamic loading.

机构信息

Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm,

出版信息

Eur Cell Mater. 2020 Jun 30;39:249-259. doi: 10.22203/eCM.v039a16.

Abstract

Postoperative implant-associated infections are a severe complication in orthopaedics and trauma surgery. To address this problem, a novel implant coating was recently developed, which allows for the release of low concentrations of bactericidal silver. For an intended use on load-bearing endoprostheses, stable bone integration is required. The aim of the present study was to evaluate the biocompatibility and osseointegration of titanium implants with the novel coating in a mechanically loaded bone-defect model in sheep. Silver-coated devices were implanted into weight-bearing and non-weight-bearing tibial and femoral bone defects whereas, in the control group, uncoated titanium implants were inserted. The bony integration of the implants was assessed mechanically and histologically after 6 months. Silver concentrations were assessed in peripheral blood, liver, kidney and local draining lymph nodes as well as at the implantation site. After 6 months, shear strength at the interface and bone apposition to the implant surface were not significantly different between coated and uncoated devices. Mechanical loading reduced bony integration independently of the coating. Silver content at the implantation site was larger in the group with silver-coated implants, yet it remained below toxic levels and no cytotoxic side effects were observed. Concluding, the novel antibacterial silver coating did not negatively influence bone regeneration or implant integration under mechanically unloaded and even loaded conditions, suggesting that the silver coating might be suitable for orthopaedic load-bearing implants, including endoprostheses.

摘要

术后植入物相关感染是骨科和创伤外科的严重并发症。为了解决这个问题,最近开发了一种新型植入物涂层,它可以释放低浓度的杀菌银。对于预期用于承重内植物的应用,需要稳定的骨整合。本研究的目的是评估新型涂层钛植入物在绵羊机械负重骨缺损模型中的生物相容性和骨整合。将带涂层的器械植入承重和非承重胫骨和股骨骨缺损中,而在对照组中,植入未涂层的钛植入物。在 6 个月后,通过机械和组织学评估植入物的骨整合。在植入物部位以及外周血、肝脏、肾脏和局部引流淋巴结中评估银浓度。6 个月后,界面剪切强度和骨与植入物表面的附着在涂层和未涂层器械之间没有显著差异。机械加载独立于涂层降低了骨整合。带涂层植入物的植入部位的银含量较大,但仍低于毒性水平,未观察到细胞毒性副作用。结论:新型抗菌银涂层在机械未加载甚至加载条件下不会对骨再生或植入物整合产生负面影响,表明银涂层可能适用于承重骨科植入物,包括内植物。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验