手术中缝合线的力学性能。

Mechanical performance of sutures in surgery.

作者信息

Thacker J G, Rodeheaver G, Kurtz L, Edgerton M T, Edich R F

出版信息

Am J Surg. 1977 Jun;133(6):713-5. doi: 10.1016/0002-9610(77)90161-1.

Abstract

In this study, we have compared the recommended configuration of a knot with specified sutures as ascertained by mechanical performance tests to that employed by a group of board-certified surgeons. Agreement between the surgeon and the results of the test was encountered in only one fourth of the instances. In another one fourth of the cases the surgeon overestimated the number of throws required for a knot to reach knot break. This additional suture material further handicaps the host's defenses, thereby inviting infection. Surgeons employed knots that untied without reaching knot break in the remaining half of the cases. The holding power of many of the knots that untied was substantially less than that of knots reaching knot break. On the basis of the study, it is recommended that results of the mechanical performance tests be made readily available to the surgeon so that his patient can receive maximal benefits from the knotted suture with the least damage to the host's defenses.

摘要

在本研究中,我们将通过机械性能测试确定的特定缝线打结的推荐构型与一组获得委员会认证的外科医生所采用的构型进行了比较。仅在四分之一的情况下,外科医生的操作与测试结果相符。在另外四分之一的病例中,外科医生高估了打结至结断裂所需的缝线缠绕次数。这些额外的缝线材料进一步削弱了宿主的防御能力,从而引发感染。在其余一半的病例中,外科医生所打的结在未达到结断裂时就松开了。许多松开的结的固定力明显低于达到结断裂的结。基于该研究,建议将机械性能测试结果及时提供给外科医生,以便其患者能够从打结缝线中获得最大益处,同时对宿主防御系统的损害最小。