Suppr超能文献

两种电子根尖定位仪与传统X线片在乳磨牙工作长度测定中的临床评估及其对儿童行为反应的影响

A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses.

作者信息

Nellamakkada Krithi, Patil Sandya S, Kakanur Madhu, Kumar Ravi S, Thakur Rachna

机构信息

Department of Pediatric and Preventive Dentistry, KLE Society's Institute of Dental Sciences and Hospital, Bengaluru, Karnataka, India.

出版信息

J Indian Soc Pedod Prev Dent. 2020 Apr-Jun;38(2):158-163. doi: 10.4103/JISPPD.JISPPD_28_20.

Abstract

BACKGROUND

Accurate root canal length determination, simplicity of the procedure, and patient's cooperation are important determinants in the success of endodontic treatment in primary teeth.

AIM

The aim of the study was to clinically compare the accuracy of Propex Pixi and Formatron D10 apex locators with conventional radiography in determining working length in mandibular primary second molars with and without varying degrees of physiological root resorption.

DESIGN

A nonrandomized clinical trial was conducted in 115 mandibular primary second molars indicated for pulpectomy in 90 pediatric dental patients. A single calibrated examiner determined the working length by conventional radiographic method and electronic apex locator (EAL) methods in a total of 376 canals. Behavior of the children during execution of each method in each tooth was recorded using the Frankl's behavior rating scale. The data obtained were tabulated and subjected to statistical analysis.

RESULTS

Significant correlation (intraclass correlation = 0.80 and 0.81, P < 0.001) could be detected between working length measurements obtained using Propex Pixi and Formatron D10 and measurements obtained using conventional radiography. Higher percentage of negative behaviors (negative and definitely negative) was observed during the conventional radiographic method (68.6%) as opposed to the Propex Pixi (16.5%) and Formatron D10 (20.8%) methods.

CONCLUSIONS

Both the apex locators were as accurate as conventional radiography in determining working length in primary teeth; Formatron D10 being more accurate than Propex Pixi. The EALs were far better accepted by children than conventional radiography.

摘要

背景

准确确定根管长度、操作的简便性以及患者的配合是乳牙牙髓治疗成功的重要决定因素。

目的

本研究的目的是在临床上比较Propex Pixi和Formatron D10根尖定位仪与传统放射照相法在确定有无不同程度生理性牙根吸收的下颌乳第二磨牙工作长度方面的准确性。

设计

对90名儿童牙科患者的115颗拟行牙髓摘除术的下颌乳第二磨牙进行了一项非随机临床试验。由一名经过校准的检查者通过传统放射照相法和电子根尖定位仪(EAL)法确定总共376个根管的工作长度。使用弗兰克尔行为评定量表记录每个儿童在每颗牙齿的每种方法操作过程中的行为。将获得的数据制成表格并进行统计分析。

结果

使用Propex Pixi和Formatron D10获得的工作长度测量值与使用传统放射照相法获得的测量值之间存在显著相关性(组内相关性分别为0.80和0.81,P<0.001)。与Propex Pixi(16.5%)和Formatron D10(20.8%)方法相比,在传统放射照相法过程中观察到更高比例的负面行为(负面和绝对负面)(68.6%)。

结论

两种根尖定位仪在确定乳牙工作长度方面与传统放射照相法一样准确;Formatron D10比Propex Pixi更准确。与传统放射照相法相比,儿童对EALs的接受度要高得多。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验