Suppr超能文献

双发射金属有机骨架:一种新型的比率型荧光传感器,用于高效、特异性检测次氯酸盐。

Dual-emissive metal-organic framework: a novel turn-on and ratiometric fluorescent sensor for highly efficient and specific detection of hypochlorite.

机构信息

Department of Applied Chemistry, College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, People's Republic of China.

Department of Chemistry, University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249-0698, USA.

出版信息

Dalton Trans. 2020 Jul 21;49(28):9680-9687. doi: 10.1039/d0dt02041a.

Abstract

Hypochlorite (ClO-) is widely used as a disinfectant, whose residue content in water should be strictly controlled due to the potential threat to human health in an inappropriate concentration. Herein, dual-emissive metal-organic frameworks with a UiO-66 prototype structure, PDA/Eu/PDA-UiO-66-NH2(x), were elegantly designed and prepared by a mixed ligand assembly and sequential post-synthesis strategy. Since blue emission is sensitive to ClO-, PDA/Eu/PDA-UiO-66-NH2(40) was selected as a model nanosensor for ratiometric and turn-on sensing of ClO- while red emission acts as a reference signal. Remarkably, PDA/Eu/PDA-UiO-66-NH2(40) shows high efficiency and specificity toward ClO- detection, as verified by a very short response time of 15 s, a wide linear range of 0.1-60 μM, a low detection limit of 0.10 μM, and excellent selectivity toward common competing ions. The recovery experiments show that the recoveries of spiking ClO- in tap water range from 96 to 103%. The rigidification of the coordinated H2N-BDC2- ligands should be responsible for the turn-on fluorescence of PDA/Eu/PDA-UiO-66-NH2(40). This work not only shows a highly efficient and specific fluorescent nanosensor for ClO- detection but also presents the first MOF-based fluorescent probe for turn-on and ratiometric sensing of ClO-.

摘要

次氯酸根(ClO-)被广泛用作消毒剂,由于其在不合适浓度下对人体健康的潜在威胁,水中的残留含量应严格控制。在此,通过混合配体组装和顺序后合成策略,巧妙地设计并制备了具有 UiO-66 原型结构的双发射金属有机骨架,PDA/Eu/PDA-UiO-66-NH2(x)。由于蓝色发射对 ClO-敏感,因此选择 PDA/Eu/PDA-UiO-66-NH2(40)作为比率和开启型 ClO-纳米传感器的模型,红色发射作为参考信号。值得注意的是,PDA/Eu/PDA-UiO-66-NH2(40)对 ClO-检测具有高效率和特异性,其响应时间为 15 s,线性范围为 0.1-60 μM,检测限低至 0.10 μM,对常见竞争离子具有出色的选择性。回收实验表明,自来水中添加的 ClO-的回收率在 96%至 103%之间。配位的 H2N-BDC2-配体的刚性化应负责 PDA/Eu/PDA-UiO-66-NH2(40)的开启荧光。这项工作不仅展示了一种用于 ClO-检测的高效且特异性的荧光纳米传感器,而且还提出了第一个基于 MOF 的荧光探针,用于 ClO-的开启和比率检测。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验