Chemicals Evaluation and Research Institute, Japan, CERI Kurume, Fukuoka, Japan.
Faculty of Environment and Information Sciences, Yokohama National University, Yokohama, Japan.
J Environ Sci Health A Tox Hazard Subst Environ Eng. 2020;55(11):1294-1303. doi: 10.1080/10934529.2020.1789410. Epub 2020 Jul 11.
Standard ready biodegradability tests are conducted at unrealistically high test concentration and therefore cannot properly evaluate toxic substances to microorganisms. The present study evaluated the effects of four adsorbent carriers in modified ready biodegradability tests of four quaternary ammonium salts (QASs) demonstrating microbial toxicity according to the Organization for Economic Co-operation and Development Test Guideline 301F and cautions for using carriers were found. In the tests with silica gel, the concentration of all QASs in the test solutions decreased due to adsorption. The percentages of biodegradation of octadecyltrimethylammonium chloride, hexadecyltrimethylammonium bromide, and benzyldimethyloctadecylammonium chloride, which have a linear alkyl chain, were 89.9%, 80.6%, and 70.1% on day 28, respectively; benzethonium chloride, with a branched alkyl chain, did not undergo biodegradation. In the tests with activated carbon, although the concentrations of QASs greatly decreased, no QASs underwent biodegradation. In the tests with sea sand or quartz sand, QASs were not adsorbed on the carriers and were not biodegraded. Using an adsorbent carrier for toxic substances will increase biodegradation, but it has no effect on highly persistent substances with specific chemical structures, e.g., branched carbons, which is very important because ready biodegradability is not overestimated. Carriers having moderate adsorbability should be selected.
标准的易生物降解性测试是在不切实际的高测试浓度下进行的,因此不能正确评估对微生物有毒的物质。本研究评估了四种吸附剂载体在四种季铵盐(QASs)改良易生物降解性测试中的作用,这些 QASs 根据经济合作与发展组织测试指南 301F 显示出微生物毒性,并发现了使用载体时的注意事项。在硅胶的测试中,由于吸附作用,所有 QASs 的测试溶液浓度都降低了。具有线性烷基链的十八烷基三甲基氯化铵、十六烷基三甲基溴化铵和苄基二甲基十八烷基氯化铵的生物降解率分别为 28 天的 89.9%、80.6%和 70.1%;具有支链烷基链的苯扎氯铵则没有发生生物降解。在活性炭的测试中,虽然 QASs 的浓度大大降低,但没有 QASs 发生生物降解。在海砂或石英砂的测试中,QASs 没有被载体吸附,也没有被生物降解。对于有毒物质,使用吸附剂载体可以增加生物降解,但对于具有特定化学结构的高度持久物质,如支链碳,这没有效果,因为不会高估易生物降解性,这一点非常重要。应该选择具有适度吸附能力的载体。