• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Microvascular polytetrafluoroethylene prostheses: the cellular events of healing and prostacyclin production.

作者信息

van der Lei B, Wildevuur C R

机构信息

Department of General Surgery, University Hospital of Groningen, The Netherlands.

出版信息

Plast Reconstr Surg. 1988 May;81(5):735-41.

PMID:3283790
Abstract

This study was undertaken to obtain more insight into the morphologic and functional performance of microvascular polytetrafluoroethylene (PTFE) prostheses. Therefore, both the cellular events of healing (n = 30) and the prostacyclin production (n = 18) of microvascular polytetrafluoroethylene prostheses (length 10 mm, internal diameter 1.5 mm) were evaluated from 1 hour up to 3 months after implantation into the abdominal aorta of rats. After implantation, the graft surface became scarcely covered with platelets. From 1 week onward, endothelial cells originating from the anastomotic sides grew in over the graft surface, covered only about half the prostheses after 3 months of implantation, but did produce normal amounts of prostacyclin as compared to normal endothelium. Only near the anastomotic sides one to two layers of smooth-muscle-like cells developed underneath the neoendothelial lining. Perigraft tissue ingrowth into the wall of the polytetrafluoroethylene prostheses was scarce. The overall patency rate was 98 percent. It was concluded that optimalization of the healing characteristics of microvascular polytetrafluoroethylene prostheses may provide a prosthesis that is more suitable for clinical microsurgery.

摘要

相似文献

1
Microvascular polytetrafluoroethylene prostheses: the cellular events of healing and prostacyclin production.
Plast Reconstr Surg. 1988 May;81(5):735-41.
2
Improved healing of small-caliber polytetrafluoroethylene prostheses by induction of a clot layer: a review of experimental studies in rats.
Int Angiol. 1991 Oct-Dec;10(4):202-8.
3
Improved healing of microvascular PTFE prostheses by induction of a clot layer: an experimental study in rats.通过诱导凝血层改善微血管聚四氟乙烯假体的愈合:大鼠实验研究
Plast Reconstr Surg. 1989 Dec;84(6):960-8. doi: 10.1097/00006534-198912000-00016.
4
Improved healing of small-caliber polytetrafluoroethylene vascular prostheses by increased hydrophilicity and by enlarged fibril length. An experimental study in rats.
J Thorac Cardiovasc Surg. 1992 Jan;103(1):146-52.
5
Experimental microvenous reconstructions with Gore-Tex polytetrafluoroethylene prosthesis implanted by means of the sleeve anastomotic technique.采用套入式吻合技术植入戈尔特斯聚四氟乙烯人工血管进行实验性微静脉重建。
Microsurgery. 1991;12(1):23-9. doi: 10.1002/micr.1920120106.
6
Patency and healing of 10-cm long microarterial polytetrafluoroethylene prostheses in the rat abdominal aorta.大鼠腹主动脉中10厘米长的微动脉聚四氟乙烯假体的通畅性与愈合情况。
J Reconstr Microsurg. 1989 Oct;5(4):331-6. doi: 10.1055/s-2007-1006882.
7
Healing of microvenous PTFE prostheses implanted into the rat femoral vein.植入大鼠股静脉的微静脉聚四氟乙烯假体的愈合情况。
Br J Plast Surg. 1993 Mar;46(2):110-5. doi: 10.1016/0007-1226(93)90140-7.
8
Enhanced healing of 30 microns Gore-Tex PTFE microarterial prostheses by alcohol-pretreatment.酒精预处理促进30微米戈尔特斯聚四氟乙烯微动脉假体的愈合
Br J Plast Surg. 1991 Aug-Sep;44(6):428-33. doi: 10.1016/0007-1226(91)90201-t.
9
Arterial wall regeneration in small-caliber vascular grafts in rats. Neoendothelial healing and prostacyclin production.大鼠小口径血管移植物的动脉壁再生。新生内皮愈合与前列环素生成。
J Thorac Cardiovasc Surg. 1985 Sep;90(3):378-86.
10
Healing of microvenous polytetrafluoroethylene (PTFE) prostheses implanted into the rat femoral vein by means of 3M precise.通过3M精密技术植入大鼠股静脉的微静脉聚四氟乙烯(PTFE)假体的愈合情况。
Ann Plast Surg. 1996 Jan;36(1):60-4. doi: 10.1097/00000637-199601000-00012.