Suppr超能文献

评估IDS RapID SS/u系统用于快速鉴定泌尿微生物的性能。

Evaluation of the IDS RapID SS/u system for rapid identification of urinary microorganisms.

作者信息

DeGirolami P C, Poliferno J S, Mills L S, Eichelberger K A

机构信息

Department of Pathology, New England Deaconess Hospital, Boston, Massachusetts 02215.

出版信息

Am J Clin Pathol. 1988 Jun;89(6):791-3. doi: 10.1093/ajcp/89.6.791.

Abstract

The accuracy of a new rapid identification system for common urinary pathogens was compared with that of conventional methods and of miniaturized 18-24-hour identification panels. The rapid system, RapID SS/u (Innovative Diagnostic System Inc., Atlanta, GA) is a non-growth-dependent micro-method that identifies selected gram-negative bacilli, gram-positive cocci, and yeasts in two hours by detection of constitutive enzymes acting on chromogenic substrates. A total of 185 representative clinical urinary isolates were tested, including 24 gram-positive cocci, 140 gram-negative bacilli, and 21 yeasts. Identifications by the rapid system were compared with the ones obtained by reference conventional methods for gram-positive cocci and yeasts. For gram-negative bacilli, identifications were compared with the ones obtained by MicroScan Combo Panel (American MicroScan, Mahwah, NJ), and all discrepancies were resolved by testing with API 20E (Analytab Products, Plainview, NY). Overall, the RapID SS/u system correctly identified to genus 160 of 185 isolates (86.5%). For 14 additional isolates (7.6%) the system provided probability overlap identifications that required further testing. Two (1%) isolates failed to be identified, and nine isolates (4.9%) were misidentified by the system. Discrepancies involved five strains of Citrobacter, one Enterobacter, one Morganella, and one Providencia species. The authors conclude that the RapID SS/u system provided rapid and accurate genus identification of most microorganisms commonly isolated from urine.

摘要

将一种用于常见尿路病原体的新型快速鉴定系统的准确性与传统方法以及小型化的18 - 24小时鉴定板的准确性进行了比较。这种快速系统,即RapID SS/u(创新诊断系统公司,佐治亚州亚特兰大),是一种非生长依赖型微量方法,通过检测作用于显色底物的组成酶,在两小时内鉴定选定的革兰氏阴性杆菌、革兰氏阳性球菌和酵母菌。总共测试了185株具有代表性的临床尿液分离株,包括24株革兰氏阳性球菌、140株革兰氏阴性杆菌和21株酵母菌。将快速系统的鉴定结果与革兰氏阳性球菌和酵母菌的参考传统方法所获得的结果进行比较。对于革兰氏阴性杆菌,将鉴定结果与通过MicroScan组合板(美国MicroScan公司,新泽西州马哈瓦)获得的结果进行比较,所有差异均通过使用API 20E(Analytab产品公司,纽约州普莱恩维尤)进行测试来解决。总体而言,RapID SS/u系统正确鉴定出了185株分离株中的160株(86.5%)到属水平。另外14株分离株(7.6%)的系统鉴定结果存在概率重叠,需要进一步测试。有2株(1%)分离株未能被鉴定出来,9株(4.9%)分离株被该系统误鉴定。差异涉及5株柠檬酸杆菌、1株肠杆菌、1株摩根氏菌和1株普罗威登斯菌属。作者得出结论,RapID SS/u系统为大多数常见于尿液中的微生物提供了快速准确的属水平鉴定。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验