Suppr超能文献

唾液pH值对模拟口腔环境下两种不同美学弓丝涂层的涂层耐久性的影响。

Effects of salivary pH on coating durability of two different aesthetic archwire coatings under a simulated intraoral environment.

作者信息

Abdulkader Youssef Chikh, Kamaruddin Anis F, Mydin Rabiatul Basria S M N

机构信息

Craniofacial & Biomaterial Sciences Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Penang, Malaysia.

Oncology & Radiology Sciences Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Penang, Malaysia.

出版信息

Saudi Dent J. 2020 Sep;32(6):306-313. doi: 10.1016/j.sdentj.2019.09.010. Epub 2019 Oct 15.

Abstract

OBJECTIVES

This study compared the effects of normal salivary pH, and acidic pH found in patients with poor oral hygiene, on the durability of aesthetic archwire coated with epoxy resin and polytetrafluoroethylene (PTFE).

METHODS

The posterior parts of the archwires were sectioned into 20 mm segments (N = 102) and divided among six groups. Four groups were treated with different pH levels and two served as controls. The specimens were immersed in individual test tubes containing 10 ml of artificial saliva adjusted to a pH of 6.75 or 3.5. The tubes were sealed and stored in a 37 °C water bath for 28 days. After 28 days, the specimens were ligated to brackets embedded in an acrylic block and subjected to mechanical stress using an electronic toothbrush for 210 s. The specimens were photographed, and images were measured for coating loss using AutoCAD® software. Surface morphology was observed using a scanning electron microscope (SEM).

RESULTS

Significant coating loss ( 0.001) was found in the epoxy resin groups, regardless of pH value, but not in the PTFE groups. The acidic pH caused epoxy resin layer coating loss by twice as much as normal pH. SEM revealed existing manufacturing defects on the as-received epoxy resin coating, whereas the retrieved epoxy resin demonstrated rupture, roughness, and coating loss in multiple locations.

SIGNIFICANCE

Epoxy resin coatings demonstrate poor durability in acidic environments. This condition is worsened by the existing manufacturing defects found on as-received archwires. Hence, archwires coated with epoxy resin are not recommended in patients with poor oral hygiene.

摘要

目的

本研究比较了正常唾液pH值以及口腔卫生差的患者所具有的酸性pH值,对涂有环氧树脂和聚四氟乙烯(PTFE)的美观弓丝耐久性的影响。

方法

将弓丝后部切成20毫米长的片段(N = 102),并分为六组。四组用不同的pH水平进行处理,两组作为对照。将标本浸入装有10毫升pH值调整为6.75或3.5的人工唾液的单独试管中。将试管密封并储存在37°C的水浴中28天。28天后,将标本结扎到嵌入丙烯酸块中的托槽上,并使用电动牙刷施加机械应力210秒。对标本进行拍照,并使用AutoCAD®软件测量图像的涂层损失。使用扫描电子显微镜(SEM)观察表面形态。

结果

无论pH值如何,在环氧树脂组中均发现有明显的涂层损失(P < 0.001),但在PTFE组中未发现。酸性pH导致环氧树脂层的涂层损失是正常pH的两倍。SEM显示,收到的环氧树脂涂层上存在制造缺陷,而回收的环氧树脂在多个位置出现破裂、粗糙度和涂层损失。

意义

环氧树脂涂层在酸性环境中耐久性较差。收到的弓丝上存在的制造缺陷使这种情况更加恶化。因此,不建议在口腔卫生差的患者中使用涂有环氧树脂的弓丝。