Suppr超能文献

在美洲感染新型亚洲基孔肯雅病毒的患者中,快速侧向流动 E1/E2-抗原检测和 ELISA 的开发和验证。

Development and Validation of a Rapid Lateral Flow E1/E2-Antigen Test and ELISA in Patients Infected with Emerging Asian Strain of Chikungunya Virus in the Americas.

机构信息

E25Bio, Cambridge, MA 02139, USA.

Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.

出版信息

Viruses. 2020 Sep 1;12(9):971. doi: 10.3390/v12090971.

Abstract

Since its 2013 emergence in the Americas, Chikungunya virus (CHIKV) has posed a serious threat to public health. Early and accurate diagnosis of the disease, though currently lacking in clinics, is integral to enable timely care and epidemiological response. We developed a dual detection system: a CHIKV antigen E1/E2-based enzyme-linked immunosorbent assay (ELISA) and a lateral flow test using high-affinity anti-CHIKV antibodies. The ELISA was validated with 100 PCR-tested acute Chikungunya fever samples from Honduras. The assay had an overall sensitivity and specificity of 51% and 96.67%, respectively, with accuracy reaching 95.45% sensitivity and 92.03% specificity at a cycle threshold (Ct) cutoff of 22. As the Ct value decreased from 35 to 22, the ELISA sensitivity increased. We then developed and validated two lateral flow tests using independent antibody pairs. The sensitivity and specificity reached 100% for both lateral flow tests using 39 samples from Colombia and Honduras at Ct cutoffs of 20 and 27, respectively. For both lateral flow tests, sensitivity decreased as the Ct increased after 27. Because CHIKV E1/E2 are exposed in the virion surfaces in serum during the acute infection phase, these sensitive and specific assays demonstrate opportunities for early detection of this emerging human pathogen.

摘要

自 2013 年在美洲出现以来,基孔肯雅病毒(CHIKV)对公共卫生构成了严重威胁。尽管目前临床上缺乏疾病的早期和准确诊断,但这对于实现及时护理和流行病学应对至关重要。我们开发了一种双重检测系统:一种基于 CHIKV 抗原 E1/E2 的酶联免疫吸附测定(ELISA)和一种使用高亲和力抗 CHIKV 抗体的侧向流动测试。该 ELISA 用来自洪都拉斯的 100 个经 PCR 检测的急性基孔肯雅热样本进行了验证。该检测方法的总体敏感性和特异性分别为 51%和 96.67%,准确性在 Ct 值截止值为 22 时达到 95.45%的敏感性和 92.03%的特异性。随着 Ct 值从 35 降低到 22,ELISA 的敏感性增加。然后,我们使用独立的抗体对开发并验证了两种侧向流动测试。使用来自哥伦比亚和洪都拉斯的 39 个样本,在 Ct 截止值为 20 和 27 时,两种侧向流动测试的敏感性和特异性均达到 100%。对于两种侧向流动测试,当 Ct 在 27 之后增加时,敏感性会降低。由于 CHIKV E1/E2 在急性感染期血清中的病毒粒子表面暴露,因此这些敏感且特异的检测方法为早期检测这种新兴的人类病原体提供了机会。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1ead/7552019/03654d037def/viruses-12-00971-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验