AIMS/INTRODUCTION: We carried out a multicenter clinical study to investigate whether the decrease in segmental phase angles (PhA values) observed using bioelectrical impedance is useful in screening for diabetes mellitus and monitoring disease progression.
The segmental PhA values of the four limbs were acquired using multifrequency bioimpedance at 5, 50 and 250 kHz in three clinics. Differences in PhA values between the diabetes and control groups were analyzed using the two-sample t-test and analysis of variance (anova). Changes in PhA values with increasing durations of diabetes were analyzed using a moderated mediation model and multivariate linear regression analysis. We recruited 217 participants aged ≥40 years (diabetes 158, controls 59, men 106, women 111, A-clinic 71, B-clinic 70 and C-clinic 76).
PhA values at 50 kHz were significantly decreased in people with diabetes (PhA of the right arm in men: t-value -4.0, P < 0.001; PhA of the right leg in women: t-value -4.6 P < 0.001), and the difference was partially attributable to the duration of diabetes, as well as aging. Specifically, the mediation effect of the duration of diabetes on the decrease in PhA values was 29.8% in the left arm of men, 53.3% in the right arm of women, and 36.3% in the left arm of both sexes.
Phase angle values at 50 kHz decreased in people with diabetes, and the changes were exacerbated as the disease duration increased. Thus, bioimpedance PhA values represent a non-invasive tool for monitoring the progression of diabetes mellitus.
目的/引言:我们进行了一项多中心临床研究,旨在探讨使用生物电阻抗测量的节段相位角(PhA 值)下降是否有助于筛查糖尿病和监测疾病进展。
在三个诊所使用多频生物阻抗仪在 5、50 和 250 kHz 频率下获取四肢的节段 PhA 值。使用两样本 t 检验和方差分析(anova)分析糖尿病组和对照组之间 PhA 值的差异。使用调节中介模型和多元线性回归分析分析 PhA 值随糖尿病持续时间的变化。我们招募了 217 名年龄≥40 岁的参与者(糖尿病 158 名,对照组 59 名,男性 106 名,女性 111 名,A 诊所 71 名,B 诊所 70 名和 C 诊所 76 名)。
糖尿病患者的 50 kHz PhA 值显著降低(男性右臂 PhA 值:t 值-4.0,P<0.001;女性右腿 PhA 值:t 值-4.6,P<0.001),差异部分归因于糖尿病持续时间和衰老。具体来说,糖尿病持续时间对 PhA 值下降的中介效应在男性左臂为 29.8%,女性右臂为 53.3%,两性左臂为 36.3%。
糖尿病患者的 PhA 值在 50 kHz 时下降,且随着疾病持续时间的增加而加剧。因此,生物电阻抗 PhA 值是监测糖尿病进展的一种非侵入性工具。