Suppr超能文献

磁共振成像安全考虑因素:前列腺 MRI 检查患者。

MR safety considerations for patients undergoing prostate MRI.

机构信息

Department of Diagnostic and Interventional Imaging, University of Texas Health Science Center at Houston, 6431 Fannin, MSB2.130B, Houston, TX, 77030, USA.

出版信息

Abdom Radiol (NY). 2020 Dec;45(12):4097-4108. doi: 10.1007/s00261-020-02730-0. Epub 2020 Sep 9.

Abstract

Over the past decade, there has been a dramatic increase in the number of patients undergoing prostate MRI scans. Patients presenting for prostate MRI are an ageing population and may present with a variety of passive or active implants and devices. These implants and devices can be MR safe or MR conditional or MR unsafe. Patients with certain MR-conditional active implants and devices can safely obtain prostate MRI in a specified MR environment within specific MR imaging parameters. Prostate MRI and PET-MRI in patients with passive implants such as hip prostheses, fiducial markers for SBRT, brachytherapy seeds and prostatectomy bed clips have unique concerns for image optimization that can cause geometric distortion of the diffusion-weighted imaging (DWI) sequence. We discuss strategies to overcome these susceptibility artifacts. Prostate MRI in patients with MR conditional active implants such as cardiac implantable electronic devices (CIED) also require modification of imaging parameters and magnet strength. In this setting, a diagnostic quality prostate MRI can be performed at a lower magnet strength (1.5 T) along with modification of imaging parameters to ensure patient safety. Imaging strategies to minimize susceptibility artifact and decrease the specific absorption rate (SAR) in both settings are described. Knowledge of MR safety considerations and imaging strategies specific to prostate MRI and PET-MRI in patients with implants and devices is essential to ensure diagnostic-quality MR images and patient safety.

摘要

在过去的十年中,接受前列腺 MRI 扫描的患者数量急剧增加。接受前列腺 MRI 的患者是一个老龄化的人群,可能会出现各种被动或主动植入物和设备。这些植入物和设备可以是磁共振安全的、磁共振条件性的或磁共振不安全的。某些具有磁共振条件性的主动植入物和设备的患者可以在特定的磁共振成像参数内的特定磁共振环境中安全地获得前列腺 MRI。带有髋关节假体、SBRT fiducial markers、近距离放射治疗种子和前列腺切除术床夹等被动植入物的患者的前列腺 MRI 和 PET-MRI 具有独特的图像优化问题,可能会导致弥散加权成像 (DWI) 序列的几何变形。我们讨论了克服这些磁化率伪影的策略。具有心脏植入式电子设备 (CIED) 等磁共振条件性主动植入物的患者的前列腺 MRI 也需要修改成像参数和磁场强度。在这种情况下,可以在较低的磁场强度(1.5T)下进行具有诊断质量的前列腺 MRI,并修改成像参数以确保患者安全。描述了在这两种情况下最小化磁化率伪影和降低特定吸收率 (SAR) 的成像策略。了解磁共振安全注意事项以及针对带有植入物和设备的患者的前列腺 MRI 和 PET-MRI 的成像策略对于确保诊断质量的磁共振图像和患者安全至关重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验