Suppr超能文献

应用剪切波弹性成像评估穿静脉功能不全:初步研究。

Evaluation of perforating venous insufficiency with shear wave elastography: a preliminary study.

机构信息

Department of Radiology, Medicine Faculty, Selçuk University, Ardıclı Mahallesi, Celal Bayar Cad. No: 313, Selçuklu, 42250, Konya, Turkey.

Department of Radiology, Kepez State Hospital, Antalya, Turkey.

出版信息

J Ultrasound. 2021 Dec;24(4):463-470. doi: 10.1007/s40477-020-00527-x. Epub 2020 Sep 9.

Abstract

PURPOSE

The aim of this study was to investigate the efficacy of shear wave elastography (SWE) in the diagnosis of perforating vein insufficiency, and to determine the applicability of these measurements.

METHODS

A total of 140 symptomatic patients with a total of 280 lower extremities were investigated. All patients presented with venous insufficiency (VI) symptoms, and received Doppler ultrasound assessment to determine VI and SWE measurements. The SWE values were measured in the adjacent perivenous tissue of the largest Cockett's perforating vein (PV) of both lower extremities, at the level where they pass the fascia. The Cockett's PV diameter and the presence of reflux in Cockett's PV and the great saphenous vein were compared with SWE values in perivenous tissue of PVs.

RESULTS

The SWE values of the perforating vein insufficiency group were significantly higher than those of the normal PV without insufficiency group (P < 0.001). A significant and positive relation was seen between increased PV diameter and SWE values (P < 0.001) and there was a significant relationship between the presence of perforating vein insufficiency and increase in PV diameter. A statistically significant increase was detected in SWE values for the PV for those with reflux in the great saphenous vein (P < 0.001). The best cut-off values that can be used to detect perforating vein insufficiency were found 34.600 for kPa and 3.375 for m/s.

CONCLUSION

SWE may be used effectively in addition to conventional Doppler ultrasound examination in diagnosing and following perforating vein insufficiency.

摘要

目的

本研究旨在探讨剪切波弹性成像(SWE)在诊断穿静脉功能不全中的作用,并确定这些测量方法的适用性。

方法

共对 140 例有症状的患者的 280 条下肢进行了研究。所有患者均有静脉功能不全(VI)症状,并接受多普勒超声评估以确定 VI 和 SWE 测量。在两条下肢通过筋膜的最大 Cockett 穿静脉(PV)的相邻静脉周围组织中测量 SWE 值,在它们穿过筋膜的水平处测量。比较 Cockett PV 直径和 Cockett PV 和大隐静脉中的反流与 PV 周围组织中的 SWE 值。

结果

穿静脉功能不全组的 SWE 值明显高于无静脉功能不全的正常 PV 组(P<0.001)。PV 直径增加与 SWE 值呈显著正相关(P<0.001),并且穿静脉功能不全的存在与 PV 直径的增加有显著关系。在大隐静脉反流的患者中,SWE 值对于 PV 的检测有明显的升高(P<0.001)。可用于检测穿静脉功能不全的最佳 SWE 值截断值为 34.600kPa 和 3.375m/s。

结论

SWE 可与常规多普勒超声检查有效结合,用于诊断和随访穿静脉功能不全。

相似文献

6
Duplex mapping of 2036 primary varicose veins.2036条原发性静脉曲张的双重映射
J Vasc Surg. 2009 Mar;49(3):681-9. doi: 10.1016/j.jvs.2008.09.062.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验