Suppr超能文献

基于剪切波弹性成像和B型超声检查结果的白内障分类比较评估

A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings.

作者信息

Ozgokce Mesut, Batur Muhammed, Alpaslan Muhammed, Yavuz Alpaslan, Batur Abdussamet, Seven Erbil, Arslan Harun

机构信息

Department of Radiology, Medical Faculty, Yuzuncu Yıl University, 65100, Van, Turkey.

Department of Ophthalmology, Medical Faculty, Yuzuncu Yıl University, Van, Turkey.

出版信息

J Ultrasound. 2019 Dec;22(4):447-452. doi: 10.1007/s40477-019-00400-6. Epub 2019 Sep 3.

Abstract

In this study, a comparison is made of the findings of B-mode ultrasound and ultrasound elastography with the Lens Opacities Classification (LOCS) grade in patients with senile cataracts. A total of 74 patients with cataracts and 32 age-matched healthy volunteers as the control group were evaluated in the departments of ophthalmology and radiology between 2016 and 2017. In the patient group, cataracts were graded according to LOCS, and B-mode sonographic appearance and elasticity measurements were recorded, after which the cataract grade and sonoelastography/B-mode ultrasound findings were compared using statistical methods. Among the 74 patients with cataracts, 38 were females (51.4%) and 36 were males (48.6%), and the mean age was 62.05 ± 7.95 (43-78) years. A Chi-square test revealed a significant relationship between ultrasound echogenicity of cataract and grade of cataract (p < 0.005). The ultrasound elastography revealed a mean shear-wave velocity of 2.90 m/s ± 0.371 (2.13-3.53) among patients with grade 3 cataracts, 3.1 m/s ± 0.45 (2.26-3.98) among patients with grade 4, 3 m/s ± 0.58 (2.35-4.60) among patients with grade 5 and 3 m/s ± 0.528 (2.31-4.50) among patients with grade 6 cataracts, and 3 m/s ± 0.258 (2.36-3.58) among the normal subjects. No statistically significant difference was noted in the analysis of variance (p > 0.005). While cataract grade and B mode echogenicity were directly proportional, there was no significant difference in lens elasticity.

摘要

在本研究中,对老年白内障患者的B型超声和超声弹性成像检查结果与晶状体混浊分类(LOCS)分级进行了比较。2016年至2017年期间,在眼科和放射科对74例白内障患者和32例年龄匹配的健康志愿者作为对照组进行了评估。在患者组中,根据LOCS对白内障进行分级,并记录B型超声图像表现和弹性测量结果,之后采用统计方法比较白内障分级与超声弹性成像/B型超声检查结果。74例白内障患者中,女性38例(51.4%),男性36例(48.6%),平均年龄为62.05±7.95(43 - 78)岁。卡方检验显示白内障的超声回声性与白内障分级之间存在显著相关性(p < 0.005)。超声弹性成像显示,3级白内障患者的平均剪切波速度为2.90 m/s±0.371(2.13 - 3.53),4级患者为3.1 m/s±0.45(2.26 - 3.98),5级患者为3 m/s±0.58(2.35 - 4.60),6级白内障患者为3 m/s±0.528(2.31 - 4.50),正常受试者为3 m/s±0.258(2.36 - 3.58)。方差分析未发现显著差异(p > 0.005)。虽然白内障分级与B型超声回声性成正比,但晶状体弹性无显著差异。

相似文献

1
A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings.
J Ultrasound. 2019 Dec;22(4):447-452. doi: 10.1007/s40477-019-00400-6. Epub 2019 Sep 3.
5
Optical coherence elastography of cold cataract in porcine lens.
J Biomed Opt. 2019 Mar;24(3):1-7. doi: 10.1117/1.JBO.24.3.036004.
8
Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.
PLoS One. 2016 Feb 18;11(2):e0149249. doi: 10.1371/journal.pone.0149249. eCollection 2016.
9
A Novel Congenital Cataract Category System Based on Lens Opacity Locations and Relevant Anterior Segment Characteristics.
Invest Ophthalmol Vis Sci. 2016 Nov 1;57(14):6389-6395. doi: 10.1167/iovs.16-20280.

引用本文的文献

1
Acute Traumatic Cataract Diagnosed by Ocular Point of Care Ultrasound (POCUS) in the Emergency Department.
POCUS J. 2025 Apr 15;10(1):107-109. doi: 10.24908/pocusj.v10i01.18110. eCollection 2025 Apr.
2
Feasibility of shear wave elastography for evaluating lens stiffness in patients with age-related cataracts: A quantitative analysis.
Heliyon. 2024 May 31;10(11):e32255. doi: 10.1016/j.heliyon.2024.e32255. eCollection 2024 Jun 15.
3
Evaluation of perforating venous insufficiency with shear wave elastography: a preliminary study.
J Ultrasound. 2021 Dec;24(4):463-470. doi: 10.1007/s40477-020-00527-x. Epub 2020 Sep 9.

本文引用的文献

1
Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses.
Ultrasound Q. 2018 Dec;34(4):233-237. doi: 10.1097/RUQ.0000000000000374.
3
Optical coherence tomography measurements with the LENTIS Mplus multifocal intraocular lens.
Graefes Arch Clin Exp Ophthalmol. 2012 Sep;250(9):1395-8. doi: 10.1007/s00417-011-1901-8. Epub 2012 Jan 4.
4
A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR.
Invest Ophthalmol Vis Sci. 2011 Sep 29;52(10):7731-7. doi: 10.1167/iovs.10-7093.
5
Quantitative assessment of lens opacities with anterior segment optical coherence tomography.
Br J Ophthalmol. 2009 Jan;93(1):61-5. doi: 10.1136/bjo.2008.137653. Epub 2008 Oct 6.
6
Cataract and surgery for cataract.
BMJ. 2006 Jul 15;333(7559):128-32. doi: 10.1136/bmj.333.7559.128.
8
2002 global update of available data on visual impairment: a compilation of population-based prevalence studies.
Ophthalmic Epidemiol. 2004 Apr;11(2):67-115. doi: 10.1076/opep.11.2.67.28158.
9
Important causes of visual impairment in the world today.
JAMA. 2003 Oct 15;290(15):2057-60. doi: 10.1001/jama.290.15.2057.
10
The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox.
Vision Res. 2001 Jun;41(14):1867-77. doi: 10.1016/s0042-6989(01)00057-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验