Department of Gastroenterology, Toyonaka Municipal Hospital, Toyonaka, Osaka, Japan.
Department of Gastroenterology and Internal Medicine, Hayashi Clinic, Suita, Osaka, Japan.
Am J Gastroenterol. 2021 Jan 1;116(1):100-105. doi: 10.14309/ajg.0000000000000838.
The global needs for a reduction in radiation exposure (RE) are increasing. Endoscopic retrograde cholangiopancreatography (ERCP) is a significant fluoroscopic procedure in the gastrointestinal field. However, the actual RE in ERCP and its annual trend are still unclear. Therefore, we examined the yearly trend of RE in ERCP.
This retrospective, single-center cohort study included consecutive cases of ERCP from September 2012 to June 2019. We measured the air kerma (AK, mGy), dose area product (DAP, Gycm2), and fluoroscopy time (FT, min). We also evaluated the annual trend of the RE before and after the fluoroscopy device update.
In total, 2,174 patients receiving ERCP were enrolled. Among these, the mean age was 74.3 years, and 913 patients were women (42.0%). The median/third quartile values of AK (mGy), DAP (Gycm2), and FT (min) were 109/234 mGy, 13.3/25.8 Gycm2, and 18.2/27.7 minutes. The annual AK, DAP, and FT from 2012 to 2019 were 138, 207, 173, 177, 106, 71.0, 45.0, and 33.3 mGy; 23, 21.4, 19, 18.3, 11.9, 9.0, 6.8, and 6.4 Gycm2; and 12.5, 12.1, 9.7, 9.8, 8.2, 10.8, 9.4, and 10.3 minutes, respectively. The corresponding values before and after the update in July 2016 were 177 and 52 mGy (P < 0.0001), 19.2 and 7.6 Gycm2 (P < 0.0001), and 10.2, and 9.9 minutes (P = 0.05), respectively.
The RE from ERCP tended to decrease every year, especially after fluoroscopy device updates.
全球对减少辐射暴露(RE)的需求正在增加。内镜逆行胰胆管造影术(ERCP)是胃肠道领域中一项重要的透视检查。然而,ERCP 中的实际 RE 及其年度趋势仍不清楚。因此,我们研究了 ERCP 中 RE 的年度趋势。
本回顾性单中心队列研究纳入了 2012 年 9 月至 2019 年 6 月连续进行的 ERCP 病例。我们测量了空气比释动能(AK,mGy)、剂量面积乘积(DAP,Gycm2)和透视时间(FT,min)。我们还评估了透视设备更新前后 RE 的年度趋势。
共纳入 2174 例接受 ERCP 的患者。其中,平均年龄为 74.3 岁,913 例为女性(42.0%)。AK(mGy)、DAP(Gycm2)和 FT(min)的中位数/第三四分位数值分别为 109/234 mGy、13.3/25.8 Gycm2 和 18.2/27.7 分钟。2012 年至 2019 年的 AK、DAP 和 FT 分别为 138、207、173、177、106、71.0、45.0 和 33.3 mGy;23、21.4、19、18.3、11.9、9.0、6.8 和 6.4 Gycm2;12.5、12.1、9.7、9.8、8.2、10.8、9.4 和 10.3 分钟。2016 年 7 月更新前后的值分别为 177 和 52 mGy(P<0.0001)、19.2 和 7.6 Gycm2(P<0.0001)和 10.2 和 9.9 分钟(P=0.05)。
ERCP 的 RE 呈逐年下降趋势,尤其是在透视设备更新后。