Hadjiconstanti Anastasia C, Messaris Gerasimos A T, Thomopoulos Konstantinos C, Panayiotakis George S
Department of Medical Physics, School of Medicine, University of Patras, 265 04 Patras, Greece.
Department of Gastroenterology, School of Medicine, University of Patras, 265 04 Patras, Greece.
Radiat Prot Dosimetry. 2017 Dec 1;177(3):243-249. doi: 10.1093/rpd/ncx037.
The patient radiation doses, in conjunction with the operator experience, in therapeutic endoscopic retrograde cholangiopancreatography (ERCP) procedures, performed in our hospital, were obtained. Ninety-six patients participated in the study and were divided into 3 groups, based on the operator experience. The dosemetric indices, fluoroscopy time (FT), cumulative dose (Ka,r) and air kerma-area product (PKA), were collected. For the total and weight banding group the third quartile values of the distribution of FT, Ka,r and PKA were 2.90 and 2.92 min, 6.89 and 6.93 mGy and 1.84 and 1.85 Gycm2, respectively, and were comparative or significantly lower than the corresponding values previously reported. Taking as a criterion the operator, the differences in the patient radiation doses were statistically significant, with the highest dose recorded for the operator of the lowest experience degree. The values obtained could contribute in establishing local and national diagnostic reference levels and in optimising ERCP procedure.
我们获取了在我院进行的治疗性内镜逆行胰胆管造影术(ERCP)过程中患者的辐射剂量,并结合了操作人员的经验。96名患者参与了该研究,根据操作人员的经验将他们分为3组。收集了剂量学指标,包括透视时间(FT)、累积剂量(Ka,r)和空气比释动能面积乘积(PKA)。对于总体组和按体重分组的组,FT、Ka,r和PKA分布的第三四分位数分别为2.90和2.92分钟、6.89和6.93毫戈瑞以及1.84和1.85戈瑞平方厘米,与先前报道的相应值相比具有可比性或显著更低。以操作人员为标准,患者辐射剂量的差异具有统计学意义,经验程度最低的操作人员记录的剂量最高。所获得的值有助于建立地方和国家诊断参考水平以及优化ERCP操作程序。