Bactec 460 放射测量仪未能检测出一名艾滋病患者的新型隐球菌菌血症。

Failure of the Bactec 460 radiometer to detect Cryptococcus neoformans fungemia in an AIDS patient.

作者信息

Robinson P G, Sulita M J, Matthews E K, Warren J R

出版信息

Am J Clin Pathol. 1987 Jun;87(6):783-6. doi: 10.1093/ajcp/87.6.783.

Abstract

Cryptococcus neoformans fungemia occurred in a patient with the acquired immunodeficiency syndrome (AIDS). The BACTEC 460 radiometer failed to detect Cryptococcus neoformans in eight aerobic BACTEC 6B culture bottles inoculated with the patient's blood. The diagnosis of cryptococcemia was established by terminal (seven-day) subculturing of 6B broth to chocolate agar, which was positive for all eight radiometrically negative blood culture bottles. It appears that radiometric measurement is not optimal for the laboratory detection of cryptococcal fungemia.

摘要

一名获得性免疫缺陷综合征(AIDS)患者发生了新型隐球菌菌血症。在接种了该患者血液的8个需氧BACTEC 6B培养瓶中,BACTEC 460放射仪未能检测到新型隐球菌。通过将6B肉汤进行终末(7天)传代培养至巧克力琼脂,确诊为隐球菌血症,结果显示所有8个放射测量呈阴性的血培养瓶均为阳性。看来放射测量对于实验室检测隐球菌菌血症并非最佳方法。