Suppr超能文献

人工耳蜗植入手术中的希尔特尔裂

Hyrtl's fissures in cochlear implant surgery.

作者信息

Xie C, Harris R

机构信息

Otolaryngology Department, Cochlear Implant Centre, St George's Hospital, London, UK.

出版信息

Cochlear Implants Int. 2021 Mar;22(2):116-120. doi: 10.1080/14670100.2020.1823127. Epub 2020 Sep 23.

Abstract

This case study presents a rare anatomical anomaly complicating cochlear implantation in the form of patent periotic ducts and Hyrtl's (tympanomeningeal) fissures. Hyrtl's fissures are transient anatomical conduits which normally ossify by the 24th week of gestation. Their persistence may cause inadvertent insertion of the cochlear implant electrode into this channel and prevent a successful outcome. This case study and a review of the relevant literature highlights the importance of recognizing this rare anomaly which is easily missed on preoperative imaging.

摘要

本病例研究呈现了一种罕见的解剖学异常,即永存耳周导管和许特尔(鼓室脑膜)裂,这使人工耳蜗植入变得复杂。许特尔裂是一种短暂的解剖通道,通常在妊娠第24周时骨化。它们的持续存在可能导致人工耳蜗植入电极意外插入该通道,从而妨碍手术成功。本病例研究及相关文献回顾强调了识别这种罕见异常的重要性,这种异常在术前影像学检查中很容易被遗漏。