Suppr超能文献

美国陆军战斗医护兵在尸体模型中使用便携式超声检测气胸超声表现的性能。

US Army Combat Medic Performance With Portable Ultrasound to Detect Sonographic Findings of Pneumothorax in a Cadaveric Model.

作者信息

Meadows Robert M, Monti Jonathan D, Umar Mohamad A, Van Arnem Kerri A, Chin Eric J, Mitchell Christopher A, Love Sue

出版信息

J Spec Oper Med. 2020 Fall;20(3):71-75. doi: 10.55460/SOPZ-STAP.

Abstract

BACKGROUND

Ultrasound, due to recent advances in portability and versatility, has become a valuable clinical adjunct in austere, resource-limited settings and is well demonstrated to be an accurate/efficient means to detect pneumothorax. The purpose of this study was to evaluate the impact of hands-on ultrasound training on ultrasound-naive US Army combat medics' ability to detect sonographic findings of pneumothorax with portable ultrasound in a cadaver model.

METHODS

Ultrasound-naive US Army combat medics assigned to conventional military units were recruited from a single US Army installation and randomized to receive either didactic training only, or "blended" (didactic and hands-on) training on ultrasound detection of pneumothorax. Blinded participants were asked to perform a thoracic ultrasound exam on ventilated human cadaver models. Primary outcome measured was sensitivity and specificity of detecting sonographic findings of pneumothorax between cohorts.

RESULTS

Forty-three participants examined a total of 258 hemithoraces. The didactic-only cohort (n = 24) detected sonographic findings of pneumothorax with a sensitivity of 68% and specificity of 57%. The blended cohort (n = 19) detected sonographic findings of pneumothorax with an overall sensitivity of 91% and specificity of 80%. Detection sensitivities were similar between B-mode versus M-mode use.

CONCLUSION

US Army combat medics can use portable U/S to detect sonographic findings of pneumothorax in a human cadaver model with high sensitivity after a brief, blended (didactic and hands-on) training intervention.

摘要

背景

由于便携性和多功能性方面的最新进展,超声已成为资源有限的艰苦环境中一项有价值的临床辅助工具,并且已充分证明它是检测气胸的准确/有效手段。本研究的目的是评估实践超声培训对初次接触超声的美国陆军战斗医护人员在尸体模型中使用便携式超声检测气胸超声表现能力的影响。

方法

从一个美国陆军驻地招募被分配到常规军事单位的初次接触超声的美国陆军战斗医护人员,并将其随机分为仅接受理论培训或接受关于气胸超声检测的“混合”(理论与实践)培训。要求不知情的参与者在通气的人体尸体模型上进行胸部超声检查。测量的主要结果是不同队列之间检测气胸超声表现的敏感性和特异性。

结果

43名参与者共检查了258个半侧胸腔。仅接受理论培训的队列(n = 24)检测气胸超声表现的敏感性为68%,特异性为57%。混合培训队列(n = 19)检测气胸超声表现的总体敏感性为91%,特异性为80%。B模式与M模式使用之间的检测敏感性相似。

结论

经过简短的混合(理论与实践)培训干预后,美国陆军战斗医护人员可以在人体尸体模型中使用便携式超声以高敏感性检测气胸的超声表现。