Abstract

PURPOSE

To determine the normal values and relationships between haloes and objective optical quality in healthy eyes.

METHODS

In this cross-sectional study, haloes, pupillary responses to light, and objective optical quality were measured with the optical quality analysis system (OQAS) and a vision monitor (MonCv3) in 138 right eyes of 138 healthy young men with mean spherical equivalent of 0.32 ± 0.47 D.

RESULTS

The mean disc halo size was 77.17 ± 25.03 arcmin. The mean objective optical quality values were as follows: objective scatter index (OSI), 0.58 ± 0.33; Strehl ratio (SR), 0.21 ± 0.05; modulation transfer function cutoff, 36.27 ± 7.98 cpd; OQAS value (OV)100%, 1.21 ± 0.27; OV20%, 0.91 ± 0.23; and OV9%, 0.59 ± 0.16. Disc halo size correlated independently with OSI ( < 0.001) and minimum pupil size ( = 0.003) by forward stepwise regression analysis (disc halo size = 16.60 + 26.24 × OSI + 11.34 × minimum pupil size; R value = 17.7%; F = 14.52; < 0.001).

CONCLUSIONS

Reference values for disc halo size and objective optical quality in healthy young subjects were established. Eyes with worse objective vision quality exhibited larger haloes.

TRANSLATIONAL RELEVANCE

The study provided the knowledge and the relationships of OQAS and halo measurements from a well-defined group of healthy young subjects. Both measurements are useful in clinical practice to help quantify the vision quality and complement each other.

摘要

目的

确定健康眼睛中光晕的正常值以及光晕与客观光学质量之间的关系。

方法

在这项横断面研究中,使用光学质量分析系统(OQAS)和视觉监测仪(MonCv3)对138名平均球镜等效度数为0.32±0.47 D的健康年轻男性的138只右眼进行了光晕、瞳孔对光反应和客观光学质量测量。

结果

视盘光晕平均大小为77.17±25.03角分。客观光学质量的平均值如下:客观散射指数(OSI)为0.58±0.33;斯特列尔比(SR)为0.21±0.05;调制传递函数截止频率为36.27±7.98周/度;OQAS值(OV)100%为1.21±0.27;OV20%为0.91±0.23;OV9%为0.59±0.16。通过向前逐步回归分析,视盘光晕大小与OSI(<0.001)和最小瞳孔大小(=0.003)独立相关(视盘光晕大小=16.60 + 26.24×OSI + 11.34×最小瞳孔大小;R值 = 17.7%;F = 14.52;<0.001)。

结论

建立了健康年轻受试者视盘光晕大小和客观光学质量的参考值。客观视觉质量较差的眼睛表现出更大的光晕。

翻译相关性

该研究提供了来自一组明确的健康年轻受试者的OQAS和光晕测量的知识及关系。这两种测量在临床实践中都有助于量化视觉质量,且相互补充。

相似文献

1
Relationships Between Haloes and Objective Visual Quality in Healthy Eyes.
Transl Vis Sci Technol. 2020 Sep 11;9(10):13. doi: 10.1167/tvst.9.10.13. eCollection 2020 Sep.
2
Analysis of related factors of optical quality in healthy Chinese adults: a community-based population study.
Chin Med J (Engl). 2020 Oct 5;133(19):2308-2314. doi: 10.1097/CM9.0000000000000994.
3
[Objective assessment of comprehensive optical quality among adults at different ages].
Zhonghua Yan Ke Za Zhi. 2016 Jan;52(1):47-50. doi: 10.3760/cma.j.issn.0412-4081.2016.01.012.
4
The impact of dry eye disease on retinal image quality in children.
Cont Lens Anterior Eye. 2024 Jun;47(3):102168. doi: 10.1016/j.clae.2024.102168. Epub 2024 Apr 18.
5
Optical Quality and Related Factors in Ocular Hypertension: Preliminary Study.
J Ophthalmol. 2016;2016:3071036. doi: 10.1155/2016/3071036. Epub 2016 May 12.
6
Optical quality and intraocular scattering in a healthy young population.
Clin Exp Optom. 2011 Mar;94(2):223-9. doi: 10.1111/j.1444-0938.2010.00535.x. Epub 2010 Nov 17.
7
Optical quality in low astigmatic eyes with or without cylindrical correction.
Graefes Arch Clin Exp Ophthalmol. 2020 Feb;258(2):451-458. doi: 10.1007/s00417-019-04501-0. Epub 2019 Oct 23.
10
Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.
PLoS One. 2015 Nov 4;10(11):e0142189. doi: 10.1371/journal.pone.0142189. eCollection 2015.

引用本文的文献

1
Effect of the chromaticity of stimuli on night vision disturbances.
Sci Rep. 2024 May 3;14(1):10183. doi: 10.1038/s41598-024-61069-4.
2
Influence of decentration of plate-haptic toric intraocular lens on postoperative visual quality.
BMC Ophthalmol. 2023 Jul 20;23(1):332. doi: 10.1186/s12886-023-03061-6.
3
Effects of brimonidine tartrate 0.2 and 0.15% ophthalmic solution on the static and dynamic pupil characteristics.
Front Med (Lausanne). 2023 May 15;10:1160414. doi: 10.3389/fmed.2023.1160414. eCollection 2023.
5
Evaluation of Disk Halo Size and Identification of Correlated Factors in Myopic Adults.
Front Med (Lausanne). 2022 Jan 28;9:743543. doi: 10.3389/fmed.2022.743543. eCollection 2022.
6
Visual performance after the deterioration of retinal image quality: induced forward scattering using Bangerter foils and fog filters.
Biomed Opt Express. 2021 Apr 23;12(5):2902-2918. doi: 10.1364/BOE.424715. eCollection 2021 May 1.

本文引用的文献

1
Minimum pupil in pupillary response to light and myopia affect disk halo size: a cross-sectional study.
BMJ Open. 2018 Apr 10;8(4):e019914. doi: 10.1136/bmjopen-2017-019914.
2
Disk halo size measured in individuals with monofocal versus diffractive multifocal intraocular lenses.
J Cataract Refract Surg. 2015 Nov;41(11):2417-23. doi: 10.1016/j.jcrs.2015.04.030.
4
Effect of femtosecond laser setting on visual performance after small-incision lenticule extraction for myopia.
Br J Ophthalmol. 2015 Oct;99(10):1381-7. doi: 10.1136/bjophthalmol-2015-306717. Epub 2015 Apr 8.
5
Objective optical quality and intraocular scattering in myopic adults.
Invest Ophthalmol Vis Sci. 2014 Aug 7;55(9):5582-7. doi: 10.1167/iovs.14-14362.
6
Relationship between halo size and forward light scatter.
Br J Ophthalmol. 2014 Oct;98(10):1389-92. doi: 10.1136/bjophthalmol-2014-304872. Epub 2014 May 9.
7
Normal values for the size of a halo produced by a glare source.
J Refract Surg. 2013 Sep;29(9):618-22. doi: 10.3928/1081597X-20130819-03.
8
Glare's causes, consequences, and clinical challenges after a century of ophthalmic study.
Am J Ophthalmol. 2012 Apr;153(4):587-93. doi: 10.1016/j.ajo.2012.01.008.
9
Optical quality and visual discrimination capacity after myopic LASIK with a standard and aspheric ablation profile.
J Refract Surg. 2011 Aug;27(8):597-601. doi: 10.3928/1081597X-20110303-01. Epub 2011 Mar 21.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验