The Clinician Reported Photonumeric Cellulite Severity Scale (CR-PCSS) and Patient Reported PCSS (PR-PCSS) are newly developed tools for assessing cellulite severity.
To report on the reliability, validity, and ability to detect a change in cellulite severity on the buttocks of adult women with the CR-PCSS and PR-PCSS.
Content validity of both scales was established through concept elicitation and cognitive interviews. Test-retest reliability was evaluated, and intra-rater (both scales) and inter-rater (CR-PCSS only) reliability were estimated using intraclass correlation coefficients (ICCs) for agreement and consistency. Ability to detect a change was determined using the Subject-Global Aesthetic Improvement Scale (GAIS) or Investigator-GAIS as anchors.
For the CR-PCSS (n = 6) at baseline and Day 2, the mean interrater ICCs were ≥0.70 and mean intrarater ICCs (95% confidence interval [CI]) were ≥0.81 (0.72-0.90) for both buttocks. For the PR-PCSS (n = 99) at baseline and Day 14, the mean test-retest reliability ICCs (95% CI) were ≥0.86 (0.79-0.91) for both buttocks. A clinically meaningful change was 1.0 point on the PR-PCSS and 1.0 on the CR-PCSS.
The CR-PCSS and PR-PCSS reliably assess cellulite severity of the buttocks and can detect a clinically meaningful change after treatment for cellulite.
临床报告光子数字脂肪团严重程度量表(CR-PCSS)和患者报告 PCSS(PR-PCSS)是新开发的评估脂肪团严重程度的工具。
报告 CR-PCSS 和 PR-PCSS 对成年女性臀部脂肪团严重程度的可靠性、有效性和变化检测能力。
通过概念启发和认知访谈确定了这两个量表的内容效度。评估了测试-重测信度,使用组内相关系数(ICC)评估了组内(两个量表)和组间(仅 CR-PCSS)的信度,以评估一致性。使用受试者总体美学改善量表(GAIS)或研究者 GAIS 作为锚定来确定检测变化的能力。
对于 CR-PCSS(n = 6)在基线和第 2 天,臀部的平均组间 ICC 均≥0.70,平均组内 ICC(95%置信区间[CI])均≥0.81(0.72-0.90)。对于 PR-PCSS(n = 99)在基线和第 14 天,臀部的平均测试-重测可靠性 ICC(95%CI)均≥0.86(0.79-0.91)。PR-PCSS 的临床有意义变化为 1.0 分,CR-PCSS 为 1.0 分。
CR-PCSS 和 PR-PCSS 可靠地评估臀部脂肪团的严重程度,并且可以在治疗脂肪团后检测到临床有意义的变化。