Suppr超能文献

VSA - 3000:一种用于中枢神经系统损伤患者的定量振动觉测试设备。

VSA-3000: A Quantitative Vibration Sensation Testing Device for Patients With Central Nervous System Injury.

作者信息

Gao Mingming, Yun Xiaoping, Zhang Tong

机构信息

School of Rehabilitation Medicine, Capital Medical University, Beijing, China.

Department of Rehabilitation Evaluation, China Rehabilitation Research Center, Beijing Bo'ai Hospital, Beijing, China.

出版信息

Front Neurol. 2020 Sep 8;11:936. doi: 10.3389/fneur.2020.00936. eCollection 2020.

Abstract

To investigate the effect of using Vibration Sensory Analyzer-3000 (VSA-3000) in patients with impaired vibration sensation caused by central nervous system injury. Prospective observational study. A university hospital for the research and clinical practice of rehabilitation. Sixty patients (30 stroke and 30 spinal cord injury) were recruited, aged between 20 and 71 years old, under stable medication. Not applicable. VSA-3000 threshold test, tuning fork test and somatosensory evoked potential (SSEP) measurement. Test-retest reliability was determined based on data collected from 60 subjects, and the intraclass correlation coefficient (ICC) for vibration perception thresholds (VPTs) was in the "substantial" range. The kappa value between VSA-3000 and SSEP was 0.877, which was higher than that of tuning fork (κ = 0.732). VSA-3000 had good diagnostic accuracy with a sensitivity of 94.8%, specificity of 92.9%, and positive-predictive value of 93.8% and negative-predictive value of 94.0%, each value was higher than that of tuning fork. The area under the receiver operating characteristic curve (AUC) of VSA-3000 was 0.95 (95% CI: 0.91 to 0.98) and that of tuning fork was 0.89 (95% CI: 0.85 to 0.95), and there was a significant difference between the two values ( = 0.0216). The types of injury and age were the independent correlates of the VPTs. The present study provides preliminary evidence that VSA-3000 is a non-invasive and convenient quantitative testing instrument with good diagnostic accuracy, and it may be useful as a screening tool for assessing impaired vibration sensation caused by central nerve injury.

摘要

探讨使用振动感觉分析仪-3000(VSA-3000)对中枢神经系统损伤所致振动觉受损患者的影响。前瞻性观察性研究。一所从事康复研究与临床实践的大学医院。招募了60例患者(30例中风患者和30例脊髓损伤患者),年龄在20至71岁之间,药物治疗稳定。不适用。进行VSA-3000阈值测试、音叉测试和体感诱发电位(SSEP)测量。基于从60名受试者收集的数据确定重测信度,振动觉阈值(VPT)的组内相关系数(ICC)处于“高度相关”范围内。VSA-3000与SSEP之间的kappa值为0.877,高于音叉的kappa值(κ = 0.732)。VSA-3000具有良好的诊断准确性,敏感性为94.8%,特异性为92.9%,阳性预测值为93.8%,阴性预测值为94.0%,每个值均高于音叉。VSA-3000的受试者工作特征曲线下面积(AUC)为0.95(95%CI:0.91至0.98),音叉的AUC为0.89(95%CI:0.85至0.95),两者之间存在显著差异(P = 0.0216)。损伤类型和年龄是VPT的独立相关因素。本研究提供了初步证据,表明VSA-3000是一种具有良好诊断准确性的非侵入性便捷定量检测仪器,可作为评估中枢神经损伤所致振动觉受损的筛查工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/957f/7505990/ca70d4400e19/fneur-11-00936-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验