Ann Biomed Eng. 2020 Nov;48(11):2531-2541. doi: 10.1007/s10439-020-02627-5. Epub 2020 Oct 6.
The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck assembly mounted on a sliding table. Based on impacts to each helmet at six impact locations and three velocities, a helmet performance score (HPS) was calculated using a linear combination of the head injury criterion (HIC) and the diffuse axonal multi-axis general evaluation (DAMAGE). To determine the on-field performance of helmets, helmet model usage, player participation, and incident concussion data were collected from the five NFL seasons and used to calculate helmet model-specific concussion rates. Comparison of laboratory HPS to the helmet model-specific concussion rates on a per play basis showed a positive correlation (r = 0.61, p < 0.001) between laboratory and on-field performance of helmet models, indicating that helmets which exhibited reduced impact severity in the laboratory tests were also generally associated with lower concussion rates on-field. Further analysis showed that NFL-prohibited helmet models exhibited a significantly higher odds of concussion (OR 1.24; 95% CI 1.04-1.47; p = 0.017) relative to other helmet models.
评估了 31 种橄榄球头盔的实验室和现场表现之间的关系,这些头盔选自 2015-2019 年美国国家橄榄球联盟(NFL)赛季中球员所戴的头盔。线性冲击器测试在装有仪器化 Hybrid III 头颈部组件的滑动台上进行,该组件安装在头盔上。根据每个头盔在六个冲击位置和三个速度下的冲击,使用头部损伤准则(HIC)和弥散性轴索多轴综合评估(DAMAGE)的线性组合计算头盔性能得分(HPS)。为了确定头盔的现场表现,从五个 NFL 赛季中收集了头盔型号的使用情况、球员参与情况和脑震荡事件数据,并用于计算头盔型号的特定脑震荡率。实验室 HPS 与每次比赛的头盔型号特定脑震荡率的比较显示,头盔模型的实验室和现场性能之间存在正相关(r=0.61,p<0.001),这表明在实验室测试中表现出冲击严重程度降低的头盔通常也与现场的较低脑震荡率相关。进一步分析表明,与其他头盔模型相比,NFL 禁止使用的头盔模型发生脑震荡的几率显著更高(OR 1.24;95%CI 1.04-1.47;p=0.017)。