Patent ductus arteriosus (PDA) with unusual morphology was diagnosed in a 3-year-old German shepherd presented for exercise intolerance. Two interventional PDA closure procedures with various Amplatzer devices and one surgical ligation were attempted to close the PDA. However, PDA closure failed with both methods due to the unusual morphology and the severe enlarged ductus ampulla. Therefore, the patient underwent an aortic covered stent placement, and successful closure of the PDA was achieved. Eight months after the procedure, the dog was free of clinical signs and no residual flow was identified through the PDA on transthoracic echocardiography. Moreover, computed tomography angiography demonstrated correct stent positioning, with no evidence of thrombus formation, damage to the stent, nor any aortic wall abnormalities. Aortic covered stent placement is a viable option in dogs with unusual PDA morphology.

摘要

动脉导管未闭(PDA)的异常形态在一只 3 岁的德国牧羊犬因运动不耐受就诊时被诊断出来。为了关闭 PDA,我们尝试了两次介入性 PDA 封堵术和一次外科结扎术,使用了各种 Amplatzer 封堵器。然而,由于异常的形态和严重扩大的动脉导管壶腹,两种方法都未能成功关闭 PDA。因此,该患者接受了主动脉覆膜支架置入术,成功地关闭了 PDA。术后 8 个月,该犬无临床症状,经胸超声心动图检查未发现 PDA 有残余分流。此外,计算机断层血管造影显示支架位置正确,无血栓形成、支架损伤或主动脉壁异常的证据。在 PDA 形态异常的犬中,主动脉覆膜支架置入术是一种可行的选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验