Shehab Njwan F, Al-Sabawi Nawal A, Alkhalidi Emad F
Department of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, Iraq.
J Int Soc Prev Community Dent. 2020 Aug 6;10(4):445-451. doi: 10.4103/jispcd.JISPCD_216_20. eCollection 2020 Jul-Aug.
Rising effects of temperature due to laser use during root canal disinfection may harm periodontium and alveolar bone. Therefore, the aim of this study was to estimate the surface root temperature of lower incisors throughout the application of different power levels and times of an 810-nm diode laser.
Sixty single-rooted extracted human lower incisor teeth were selected and chemomechanical preparation was performed. Specimens were irradiated using 810-nm diode laser at 1.05, 1.5, and 1.95 W power settings and two periods of time 20 and 60s, in a continuous wave (CW) mode, without water spray. Specimens were divided into three main groups ( = 20). Each group was subdivided into two subgroups ( = 10). Then, the peak temperatures at the middle and apical regions of the root surface were registered using a thermocouple.
Temperature rise of root surface at all the selected output powers was below 7°C. The highest temperature value was obtained in the apical region at 60s when the root canal irradiated at 1.95 W output power.
Diode laser is safe for use as a root canal disinfectant. Time of exposure to laser irradiation has an effect on the temperature difference at different output powers.
根管消毒过程中激光使用导致的温度升高效应可能会损害牙周组织和牙槽骨。因此,本研究的目的是评估在不同功率水平和照射时间下,810纳米二极管激光对下颌切牙牙根表面温度的影响。
选取60颗单根拔除的人下颌切牙进行化学机械预备。标本在连续波(CW)模式下,不喷水,使用810纳米二极管激光,功率设置为1.05、1.5和1.95瓦,照射时间为20秒和60秒。标本分为三个主要组(每组20个)。每组再细分为两个亚组(每组10个)。然后,使用热电偶记录牙根表面中部和根尖区域的峰值温度。
在所有选定的输出功率下,牙根表面温度升高均低于7°C。当根管以1.95瓦输出功率照射60秒时,根尖区域获得最高温度值。
二极管激光作为根管消毒剂使用是安全的。激光照射时间对不同输出功率下的温差有影响。