He Xueying, Tang Juli, Wen Xiantao, Guan Bo, Wang Rui, Wang Hui, Li Hua, Shi Jianfeng, Zeng Yali, Mao Yongjian
Beijing Institute of Medical Device Testing, Beijing, 101111.
Beijing Key Laboratory of Medical Device Testing and Safety Evaluation, Beijing, 101111.
Zhongguo Yi Liao Qi Xie Za Zhi. 2020 Oct 8;44(5):448-452. doi: 10.3969/j.issn.1671-7104.2020.05.016.
The purpose of this study was to investigate the NOAEL of the nickel ion and provide with basic data for the biological evaluation of those medical devices containing nickel. Five groups SD rats were repeatedly exposed during 14 d respectively to nickel at first stage doses of 4.9, 3.7, 2.5 mg/(kg.d), and the second stage doses of 1.2, 0.25 mg/(kg.d) by the intravenous route. The results showed that the NOAEL of nickel ion is 0.25 mg/(kg.d) for SD rats, and the result was verified by subchronic systemic toxicity test of nickel alloy. The threshold of toxicological concern (TTC) of nickel is 150 μg/d (based on application of 100-fold uncertainty factor and a body weight of 60 kg)deduced by these data.