Suppr超能文献

由于 CT 图像采集和重建的差异导致的放射组学特征可变性的协调:在尸体肝脏中的评估。

Harmonization of radiomic feature variability resulting from differences in CT image acquisition and reconstruction: assessment in a cadaveric liver.

机构信息

Department of Radiology, University of Chicago, Chicago, IL, 60637, United States of America.

出版信息

Phys Med Biol. 2020 Oct 16;65(20):205008. doi: 10.1088/1361-6560/abb172.

Abstract

Studies investigating the effects of computed tomography (CT) image acquisition and reconstruction parameters have mostly been limited to non-human phantoms to limit exposure to patients. This study investigates these variations using a cadaveric liver and determines harmonization methods to mitigate these variations. A reference CT scan of a cadaveric liver was acquired along with 16 modified scans. Modified scans were obtained with altered image acquisition and reconstruction parameters. In each slice, the liver was segmented and used to calculate 142 features. Student's t-tests assessed differences between reference and modified scans for each feature after correcting for multiple comparisons. Features were harmonized between reference and modified scans using histogram normalization, pixel resampling, Butterworth filtering, resampling and filtering combined, and ComBat harmonization. The number of features reflecting significant differences before and after harmonization were compared across imaging parameters. Reducing the field-of-view (FOV) and using coronal instead of axial scans resulted in the greatest number of features reflecting significant differences (67.6%, and 35.9%, respectively) and resulted in the greatest median relative change in feature values (25.4% and 18.2%, respectively). Changes in tube voltage, pitch, and slice interval resulted in the smallest number of features reflecting significance (0.7%) with median relative changes in feature <2%. Histogram normalization reduced or maintained the number of significantly different features for all scans, while ComBat reduced the number of significantly different features to zero for all scans. The remaining harmonization methods had mixed effects: resampling reduced the number of features reflecting significant differences for half of the imaging parameters, while filtering alone and filtering combined with resampling both reduced the number of features reflecting significance for 10 of the 16 parameters. The dependence of radiomic features on image acquisition and reconstruction parameters varies in a cadaveric liver; however, various harmonization methods have shown promise in mitigating these dependencies, particularly ComBat.

摘要

研究人员主要通过非人体体模来研究计算机断层扫描(CT)图像采集和重建参数的影响,以限制患者的辐射暴露。本研究使用尸体肝脏来研究这些变化,并确定了协调这些变化的方法。获取了一具尸体肝脏的参考 CT 扫描和 16 个改良扫描。改良扫描是通过改变图像采集和重建参数获得的。在每个切片中,对肝脏进行分割,并用于计算 142 个特征。在对多个比较进行校正后,对每个特征的参考扫描和修改扫描之间的差异使用学生 t 检验进行评估。使用直方图归一化、像素重采样、巴特沃斯滤波、重采样和滤波结合以及 ComBat 协调来协调参考扫描和修改扫描之间的特征。比较了成像参数前后反映显著差异的特征数量。缩小视野(FOV)并使用冠状扫描而不是轴向扫描导致反映显著差异的特征数量最多(分别为 67.6%和 35.9%),特征值的中位数相对变化最大(分别为 25.4%和 18.2%)。管电压、螺距和切片间隔的变化导致反映显著意义的特征数量最少(0.7%),特征值的中位数相对变化<2%。直方图归一化减少或维持了所有扫描中显著不同特征的数量,而 ComBat 减少了所有扫描中显著不同特征的数量到零。其余的协调方法效果不一:重采样减少了一半成像参数反映显著差异的特征数量,而单独滤波和滤波与重采样结合都减少了 10 个参数中反映显著意义的特征数量。体模中放射组学特征对图像采集和重建参数的依赖性各不相同;然而,各种协调方法在减轻这些依赖性方面显示出了一定的前景,特别是 ComBat。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验