采用迷宫状掺硼碳纳米墙电极,高选择性阻抗法测定流感嗜血杆菌蛋白 D。

Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes.

机构信息

Gdańsk University of Technology, 11/12 G. Narutowicza St., 80-233, Gdańsk, Poland.

Institute of Biotechnology and Molecular Medicine, 3 Trzy Lipy St., 80-172, Gdańsk, Poland.

出版信息

Talanta. 2021 Jan 1;221:121623. doi: 10.1016/j.talanta.2020.121623. Epub 2020 Sep 9.

Abstract

This study reports a novel impedimetric immunosensor for protein D detection in purified and bacterial (Haemophilus influenzae, Hi) samples. The detection was based on antigen recognition by anti-protein D antibodies (apD) immobilised at the maze-like boron-doped carbon nanowall electrodes (B:CNW). The B:CNW electrodes were synthesised, and their surface was characterised by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) methods. The sensor was prepared in a two-step procedure: apD were covalently linked on the previously modified B:CNW electrodes using diazonium salt. Modification steps were controlled by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) measurements. The immunosensor exhibited excellent electrochemical performance, stability, satisfactory sensitivities, and linear ranges for antigen detection. Protein D was detected down to 2.39 × 10fg/mL with a linear range extending from 3.37 × 10to 3.37 × 10μg/mL (in purified sample). Next, Hi's LOD was 5.20 × 10CFU/mL with a linear range of 8.39 × 10-8.39 × 10CFU/mL. Selectivity studies showed no reaction with negative samples as Streptococcus pyogenes, Streptococcus pneumoniae or Bordetella parapertussis bacteria. Therefore, the new approach is suitable for rapid and quantitative detection of Hi, and is a good candidate for further tests on clinical samples.

摘要

本研究报告了一种用于在纯化和细菌(流感嗜血杆菌,Hi)样品中检测蛋白 D 的新型阻抗免疫传感器。该检测基于固定在迷宫状掺硼碳纳米墙电极(B:CNW)上的抗蛋白 D 抗体(apD)对抗原的识别。B:CNW 电极通过扫描电子显微镜(SEM)和 X 射线光电子能谱(XPS)方法进行了合成和表面表征。传感器通过两步程序制备:apD 通过重氮盐共价连接到先前修饰的 B:CNW 电极上。修饰步骤通过电化学阻抗谱(EIS)和循环伏安法(CV)测量进行控制。该免疫传感器表现出优异的电化学性能、稳定性、令人满意的灵敏度和线性范围,可用于抗原检测。蛋白 D 的检测下限低至 2.39×10fg/mL,线性范围从 3.37×10 到 3.37×10μg/mL(在纯化样品中)。接下来,Hi 的 LOD 为 5.20×10CFU/mL,线性范围为 8.39×10-8.39×10CFU/mL。选择性研究表明,与阴性样品(如化脓性链球菌、肺炎链球菌或百日咳博德特氏菌)无反应。因此,该新方法适用于快速定量检测 Hi,是进一步对临床样品进行测试的良好候选者。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验