Suppr超能文献

PROMISE-2 研究中慢性偏头痛患者 6 项头痛影响测试的信度和效度。

Reliability and validity of the 6-item Headache Impact Test in chronic migraine from the PROMISE-2 study.

机构信息

Vector Psychometric Group, LLC, Chapel Hill, NC, USA.

Lundbeck Seattle BioPharmaceuticals, Inc, Bothell, WA, USA.

出版信息

Qual Life Res. 2021 Mar;30(3):931-943. doi: 10.1007/s11136-020-02668-2. Epub 2020 Oct 20.

Abstract

PURPOSE

We examined the reliability and validity of the 6-item Headache Impact Test (HIT-6) specifically on patients with chronic migraine (CM) from the PROMISE-2 clinical trial.

METHODS

The conceptual framework of HIT-6 was evaluated using baseline data from the PROMISE-2 study (NCT02974153; N = 1072). A unidimensional graded response model within the item response theory (IRT) framework was used to evaluate model fit and item characteristics. Using baseline and week 12 data, convergent and discriminant validity of the HIT-6 was evaluated by correlation coefficients. Sensitivity to change was assessed by evaluating correlations between HIT-6 scores and change scores for other established reference measures. All examined correlations were specified a priori with respect to direction and magnitude. Known-groups analyses were anchored using Patient Global Impression of Change and monthly headache days at week 12.

RESULTS

A unidimensional model fit the data well, supporting that the 6 items measure a single construct. All item slopes and thresholds were within acceptable ranges. In both the validity and sensitivity to change analyses, all observed correlations conformed to directional expectations, and most conformed to magnitude expectations. Known-groups analyses demonstrated that the HIT-6 total score can distinguish between clinically meaningful CM subgroups.

CONCLUSION

The HIT-6 was successfully calibrated using IRT with data from PROMISE-2. Results from these analyses were generally consistent with previous literature and provided supportive evidence that the HIT-6 is well suited for measuring the impact of headache and migraine in the CM population.

摘要

目的

我们检验了头痛影响测试(HIT-6)在 PROMISE-2 临床试验中针对慢性偏头痛(CM)患者的可靠性和有效性。

方法

使用 PROMISE-2 研究的基线数据(NCT02974153;N=1072)评估 HIT-6 的概念框架。在项目反应理论(IRT)框架内使用单维等级反应模型评估模型拟合度和项目特征。使用基线和第 12 周的数据,通过相关系数评估 HIT-6 的聚合和区分效度。通过评估 HIT-6 评分与其他既定参考测量的变化评分之间的相关性来评估对变化的敏感性。所有检查的相关性都根据方向和大小进行了预先指定。使用第 12 周的患者整体变化印象和每月头痛天数作为已知组分析的基准。

结果

单维模型很好地拟合了数据,支持这 6 个项目衡量一个单一的结构。所有项目斜率和阈值都在可接受的范围内。在有效性和对变化的敏感性分析中,所有观察到的相关性都符合方向预期,并且大多数符合大小预期。已知组分析表明,HIT-6 总分可以区分具有临床意义的 CM 亚组。

结论

使用 IRT 对 PROMISE-2 数据进行校准后,HIT-6 成功完成了校准。这些分析的结果与先前的文献基本一致,为 HIT-6 非常适合在 CM 人群中测量头痛和偏头痛的影响提供了支持性证据。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9124/7952287/846742ad2b63/11136_2020_2668_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验