Abstract

PURPOSE

To compare the ciliary muscle thickness (CMT) of the normal fellow eye to that of the amblyopic eye using ultrasound biomicroscopy (UBM) in patients with unilateral anisometropic amblyopia.

METHODS

Thirty patients with unilateral anisometropic amblyopia were involved. The patients were divided into two groups: 19 hyperopic and 11 myopic. Axial length (AL) was measured with optic biometry and anterior chamber depth (ACD), iris area, and CMT were measured with UBM.

RESULTS

The mean age was 34.10 ± 6.61 years. The mean spherical difference between two eyes was 2.59 diopter (D) in hyperopic patients and 3.77D in myopic patients. In the hyperopic patients, nasal CMT1(nCMT), temporal CMT1(tCMT), tCMT2, and tCMT3 values were statistically thinner in amblyopic eyes than healthy eyes (p = 0.036, p = 0.003, p = 0.023, p = 0.005, respectively). ACD values were statistically lower in amblyopic eyes (2.78 ± 0.26 mm) than healthy eyes (2.90 ± 0.21 mm) (p < 0.001). In the myopic patients, nCMT1, nCMT2, nCMT3, tCMT1, tCMT2, and tCMT3 values were statistically thicker in amblyopic eyes than healthy eyes (p = 0.003, p = 0.003, p = 0.005, p = 0.003, p = 0.003, p = 0.019, respectively). ACD values were statistically higher in amblyopic eyes (3.20 ± 0.30 mm) than healthy eyes (3.06 ± 0.29 mm) (p = 0.004). Also, there was no significant difference in the iris area between the amblyopic and normal eyes of the myopic and hyperopic patients (p > 0.05).

CONCLUSIONS

Amblyopic eyes in patients with unilateral myopic anisometropia have thicker CMT and deeper ACD than healthy eyes. Conversely, amblyopic eyes in patients with unilateral hyperopic anisometropia have thinner CMT and shorter ACD than healthy eyes. There is a positive correlation between AL and CMT.

摘要

目的

使用超声生物显微镜(UBM)比较单侧屈光参差性弱视患者正常眼和弱视眼的睫状肌厚度(CMT)。

方法

纳入 30 例单侧屈光参差性弱视患者。患者分为两组:19 例远视和 11 例近视。使用光学生物测量仪测量眼轴长度(AL),使用 UBM 测量前房深度(ACD)、虹膜面积和 CMT。

结果

平均年龄为 34.10±6.61 岁。双眼的平均球镜差异在远视患者中为 2.59 屈光度(D),在近视患者中为 3.77D。在远视患者中,弱视眼的鼻侧 CMT1(nCMT1)、颞侧 CMT1(tCMT1)、tCMT2 和 tCMT3 值均明显小于正常眼(p=0.036、p=0.003、p=0.023、p=0.005)。弱视眼的 ACD 值明显低于正常眼(2.78±0.26mm)(p<0.001)。在近视患者中,弱视眼的 nCMT1、nCMT2、nCMT3、tCMT1、tCMT2 和 tCMT3 值均明显大于正常眼(p=0.003、p=0.003、p=0.005、p=0.003、p=0.003、p=0.019)。弱视眼的 ACD 值明显高于正常眼(3.20±0.30mm)(p=0.004)。此外,近视和远视患者的弱视眼和正常眼的虹膜面积无显著差异(p>0.05)。

结论

单侧近视性屈光参差性弱视患者的弱视眼的 CMT 较厚,ACD 较深。相反,单侧远视性屈光参差性弱视患者的弱视眼的 CMT 较薄,ACD 较短。AL 与 CMT 呈正相关。