Suppr超能文献

在美国国家标准与技术研究院(NIST)进行的国际计量局(BIPM)放射性计量(RI)(II)-K4.F-18和BIPM.RI(II)-K4.Cu-64持续比对中,对放射性核素氟(F)和铜(Cu)的活度测量。

Activity measurements of the radionuclides F and Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64.

作者信息

Michotte C, Nonis M, Bergeron D, Cessna J, Fitzgerald R, Pibida L, Zimmerman B, Fenwick A, Ferreira K, Keightley J, Da Silva I

机构信息

Bureau International des Poids et Mesures (BIPM).

National Institute of Standards and Technology (NIST), USA.

出版信息

Metrologia. 2017;54(1A). doi: https://doi.org/10.1088/0026-1394/54/1a/06011.

Abstract

In 2016, comparisons of activity measurements of F and Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for Cu. Ampoules containing about 27 kBq of F and 100 kBq of Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001.

摘要

2016年,在美国国家标准与技术研究院(NIST)对使用国际参考系统转移仪器(SIRTI)进行的氟和铜活度测量进行了比较。这是首次针对铜的SIRTI比较。分别在SIRTI中对含有约27 kBq氟溶液和100 kBq铜溶液的安瓿进行了约5个和1.5个半衰期的测量。NIST通过可追溯到4π(LS)β-γ反符合测量的电离室测量对安瓿中的活度进行了标准化。这些比较,标识符为BIPM.RI(II)-K4.F-18和BIPM.RI(II)-K4.Cu-64,与相应的BIPM.RI(II)-K1.F-18和BIPM.RI(II)-K1.Cu-64比较相关联,并且已经评估了与各自关键比较参考值的等效程度。NIST取代了其在2001年CCRI(II)-K3.F-18比较框架中获得的早期氟等效程度。

相似文献

2
The first official measurement of C in the SIRTI.
Appl Radiat Isot. 2019 Dec;154:108834. doi: 10.1016/j.apradiso.2019.108834. Epub 2019 Aug 3.
3
Calibration of KRISS reference ionization chamber for key comparison of (99m)Tc measurement.
Appl Radiat Isot. 2012 Sep;70(9):1853-5. doi: 10.1016/j.apradiso.2012.02.026. Epub 2012 Feb 24.
4
5
Results of an international comparison of activity measurements of Ge.
Appl Radiat Isot. 2018 Apr;134:385-390. doi: 10.1016/j.apradiso.2017.10.052. Epub 2017 Nov 7.
6
Activity measurement of mixed complex radionuclide like Eu with different methods.
Appl Radiat Isot. 2022 Jul;185:110228. doi: 10.1016/j.apradiso.2022.110228. Epub 2022 Apr 7.
7
Comparison of (18)F activity measurements at the VNIIM, NPL and the ENEA-INMRI using the SIRTI of the BIPM.
Appl Radiat Isot. 2016 Mar;109:17-23. doi: 10.1016/j.apradiso.2015.11.087. Epub 2015 Nov 28.
8
Comparison of (99m)Tc activity measurements at the KRISS using the new SIRTI of the BIPM.
Appl Radiat Isot. 2012 Sep;70(9):1820-4. doi: 10.1016/j.apradiso.2012.02.048. Epub 2012 Feb 28.
9
Comparison of the NIST and BIPM Medium-Energy X-Ray Air-Kerma Measurements.
J Res Natl Inst Stand Technol. 2003 Oct 1;108(5):383-9. doi: 10.6028/jres.108.032. Print 2003 Sep-Oct.
10
Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays.
J Res Natl Inst Stand Technol. 2006 Oct 1;111(5):385-91. doi: 10.6028/jres.111.028. Print 2006 Sep-Oct.

引用本文的文献

2
Accurate integral counting using multi-channel analyzers.
Appl Radiat Isot. 2020 May;159:109101. doi: 10.1016/j.apradiso.2020.109101. Epub 2020 Feb 27.
3
Standardization of Cu activity.
Appl Radiat Isot. 2018 Sep;139:266-273. doi: 10.1016/j.apradiso.2018.05.023. Epub 2018 May 25.
4
Monte Carlo based approach to the LS–NaI 4πβ–γ anticoincidence extrapolation and uncertainty.
Appl Radiat Isot. 2016 Mar;109:308-13. doi: 10.1016/j.apradiso.2015.11.107.
5
Consultative committee on ionizing radiation: Impact on radionuclide metrology.
Appl Radiat Isot. 2016 Mar;109:12-16. doi: 10.1016/j.apradiso.2015.11.085. Epub 2015 Nov 27.
6
A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.
J Res Natl Inst Stand Technol. 2014 Aug 27;119:371-96. doi: 10.6028/jres.119.013. eCollection 2014.

本文引用的文献

1
Standardization of Cu activity.
Appl Radiat Isot. 2018 Sep;139:266-273. doi: 10.1016/j.apradiso.2018.05.023. Epub 2018 May 25.
2
Corrections for the combined effects of decay and dead time in live-timed counting of short-lived radionuclides.
Appl Radiat Isot. 2016 Mar;109:335-340. doi: 10.1016/j.apradiso.2015.11.108. Epub 2015 Dec 2.
3
A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.
J Res Natl Inst Stand Technol. 2014 Aug 27;119:371-96. doi: 10.6028/jres.119.013. eCollection 2014.
4
A new NIST primary standardization of 18F.
Appl Radiat Isot. 2014 Feb;85:77-84. doi: 10.1016/j.apradiso.2013.11.116. Epub 2013 Dec 4.
5
MTR2: a discriminator and dead-time module used in counting systems.
Appl Radiat Isot. 2000 Mar;52(3):441-6. doi: 10.1016/s0969-8043(99)00192-x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验