Yan Tingting, Zhang Zhaowei, Zhang Qi, Tang Xiaoqian, Wang Du, Hu Xiaofeng, Zhang Wen, Chen Xiaomei, Li Peiwu
Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, 430062, China.
Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan, 430062, China.
Mikrochim Acta. 2020 Nov 11;187(12):653. doi: 10.1007/s00604-020-04623-x.
To simultaneously detect two metabolites of Aspergillus flavus, namely, cyclopiazonic acid (CPA) and aflatoxin (AFT), an ultrasensitive monoclonal antibody (mAb) YTT-2 against CPA was developed and characterized, with sensitivity to CPA of 1.32 ng mL. Along with the previously homemade mAb 1C11 against AFT, two mAbs were used to develop time-resolved fluorescence immunoprobes or gold immunoprobes. We developed two multiple-analyte paper immunosensors including time-resolved fluorescent immunochromatographic assay (TRFICA) and gold immunochromatographic assay (GICA) for the simultaneous determination of CPA and AFT. The TRFICA showed limits of determination (LODs) of 0.21 and 0.004 ng mL, while the GICA showed LODs of 0.33 and 0.01 ng mL for CPA and AFT, respectively. To validate the specificity of the two rapid immunoassays, rice, corn and peanut samples were spiked with different concentrations of CPA and AFT. The two methods showed satisfactory recoveries (76.3990.82% for CPA and 84.6094.45% for AFT) and coefficients of variation of 3.507.80% for CPA and 4.1213.90% for AFT. The results indicated that the TRFICA could complete the test within 5 min and had lower LODs and linear ranges, compared with that of GICA. The method developed in this work can be widely applied to the rapid and quantitative simultaneous determination of multiple harmful metabolites in fungi for food safety and health care. Graphical abstract.
为了同时检测黄曲霉的两种代谢产物,即环匹阿尼酸(CPA)和黄曲霉毒素(AFT),开发并表征了一种针对CPA的超灵敏单克隆抗体(mAb)YTT-2,其对CPA的灵敏度为1.32 ng/mL。连同之前自制的针对AFT的单克隆抗体1C11,使用这两种单克隆抗体开发了时间分辨荧光免疫探针或金免疫探针。我们开发了两种多分析物纸质免疫传感器,包括时间分辨荧光免疫层析测定法(TRFICA)和金免疫层析测定法(GICA),用于同时测定CPA和AFT。TRFICA对CPA和AFT的测定限(LOD)分别为0.21和0.004 ng/mL,而GICA对CPA和AFT的LOD分别为0.33和0.01 ng/mL。为了验证这两种快速免疫测定法的特异性,在大米、玉米和花生样品中添加不同浓度的CPA和AFT。这两种方法显示出令人满意的回收率(CPA为76.39%至90.82%,AFT为84.60%至94.45%),CPA的变异系数为3.50%至7.80%,AFT的变异系数为4.12%至13.90%。结果表明,与GICA相比,TRFICA可在5分钟内完成检测,且具有更低的LOD和线性范围。本研究中开发的方法可广泛应用于食品真菌中多种有害代谢产物的快速定量同时测定,以保障食品安全和医疗保健。图形摘要。