Suppr超能文献

清醒志愿者基于 SedLine 的处理脑电图参数的正常值:一项前瞻性观察研究。

Normative values for SedLine-based processed electroencephalography parameters in awake volunteers: a prospective observational study.

机构信息

Department of Intensive Care, Austin Hospital, Heidelberg, VIC, Australia.

Department of Anaesthesia and Intensive Care, IRCCS San Raffaele Scientific Institute, Milan, Italy.

出版信息

J Clin Monit Comput. 2021 Dec;35(6):1411-1419. doi: 10.1007/s10877-020-00618-4. Epub 2020 Nov 11.

Abstract

Processed electroencephalography (pEEG) is used to monitor depth of anaesthesia and/or sedation. A novel device (SedLine®) has been recently introduced into clinical practice. However, there are no published data on baseline SedLine values for awake adult subjects. We aimed to determine baseline values for SedLine-derived parameters in eyes-open and eyes-closed states. We performed a prospective observational study in healthy volunteers. SedLine EEG-derived parameters were recorded for 2 min with eyes closed and 8 min with eyes open. We determined the overall reference range for each value, as well as the reference range in each phase. We investigated changes in recorded parameters between the two phases, and the interaction between EMG, baseline characteristics, and Patient State Index (PSI). We collected data from 50 healthy volunteers, aged 23-63 years. Median PSI was 94 (92-95) with eyes open and 88 (87-91) with eyes closed (p < 0.001 for open versus close). EMG activity decreased from 47.2% (46.6-47.9) with eyes open to 28.6% (28.0-29.3) with eyes closing (p < 0.001). There was a significant positive correlation between EMG and PSI with eyes closed (p = 0.01) but not with eyes open, which was confirmed with linear regression analysis (p = 0.01). In awake volunteers, keeping eyes open induces significant changes to SedLine-derived parameters, most likely due to increased EMG activity (e.g. eye blinking). These findings have implications for the clinical interpretation of PSI parameters and for the planning of future research.

摘要

处理后的脑电图 (pEEG) 用于监测麻醉深度和/或镇静程度。一种新型设备 (SedLine®) 最近已应用于临床实践。然而,目前尚无关于清醒成年患者的 SedLine 基线值的相关报道。本研究旨在确定睁眼和闭眼状态下 SedLine 衍生参数的基线值。我们进行了一项前瞻性观察性研究,纳入了健康志愿者。记录 SedLine 脑电图衍生参数,闭眼 2 分钟,睁眼 8 分钟。我们确定了每个值的总体参考范围,以及每个阶段的参考范围。我们研究了两个阶段之间记录参数的变化,以及肌电图、基线特征和患者状态指数 (PSI) 之间的相互作用。我们共纳入了 50 名年龄为 23-63 岁的健康志愿者。睁眼时 PSI 中位数为 94(92-95),闭眼时为 88(87-91)(睁眼与闭眼相比,p<0.001)。肌电图活动从睁眼时的 47.2%(46.6-47.9)下降至闭眼时的 28.6%(28.0-29.3)(睁眼与闭眼相比,p<0.001)。闭眼时 PSI 与肌电图呈显著正相关(p=0.01),但睁眼时无相关性,这一结果也通过线性回归分析得到了证实(p=0.01)。在清醒志愿者中,睁眼会引起 SedLine 衍生参数的显著变化,这可能是由于肌电图活动增加(如眨眼)所致。这些发现对 PSI 参数的临床解释和未来研究的规划具有重要意义。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验