Silicone passive samplers were assessed for measuring personal exposure to 37 flame retardants at three Québec e-waste recycling facilities. Silicone brooches ( = 45), wristbands ( = 28), and armbands ( = 9) worn during a ∼8 h work shift accumulated detectable amounts of 95-100% of the target compounds. Brooch concentrations were significantly correlated with those from active air samplers from which we conclude that the brooches could be used to approximate inhalation exposure and other exposures related to air concentrations such as dermal exposure. The generic sampling rate of the brooch (19 ± 11 m day dm) was 13 and 22 times greater than estimated for home and office environments, respectively, likely because of the dusty work environment and greater movement of e-waste workers. BDE-209 concentrations in brooches and wristbands were moderately and significantly ( < 0.05) correlated with levels in blood plasma; organophosphorus esters in brooches and wristbands were weakly and insignificantly correlated with their metabolite biomarkers in post-shift spot urine samples. Silicone brooches and wristbands deployed over a single shift in a dusty occupational setting can be useful for indicating the internal exposure to compounds with relatively long biological half-lives, but their use for compounds with relatively short half-lives is not clear and may require either a longer deployment time or an integrated biomarker measure.
硅酮被动采样器被评估用于测量 37 种阻燃剂在魁北克三个电子废物回收设施中的个人暴露情况。在大约 8 小时的工作班次中,佩戴的硅酮胸针(= 45)、腕带(= 28)和臂带(= 9)积累了可检测量的 95-100%的目标化合物。胸针浓度与我们从主动空气采样器中得出的浓度显著相关,这表明胸针可以用来近似吸入暴露和其他与空气浓度相关的暴露,如皮肤暴露。胸针的通用采样率(19 ± 11 m day dm)分别是家庭和办公室环境的 13 倍和 22 倍,这可能是由于工作环境灰尘较多和电子废物工人的活动量较大。胸针和腕带中的 BDE-209 浓度与血浆中的水平呈中度和显著相关(<0.05);胸针和腕带中的有机磷酯与工作后尿液样本中的代谢物生物标志物呈弱且无显著相关性。在灰尘弥漫的工作环境中,单次轮班佩戴硅酮胸针和腕带可以用于指示具有相对较长生物半衰期的化合物的内部暴露,但它们在具有相对较短半衰期的化合物的应用尚不清楚,可能需要更长的部署时间或综合生物标志物测量。