Suppr超能文献

可植入 Collamer 透镜眼的瞳孔不等大和高拱的处理。

Management of anisocoria and high vault in an eye with implantable collamer lens.

机构信息

Department of Cornea and Refractive Surgery, Anand Eye Institute, Hyderabad, Telangana, India.

Department of Glaucoma, Anand Eye Institute, Hyderabad, Telangana, India.

出版信息

Indian J Ophthalmol. 2020 Dec;68(12):3070-3072. doi: 10.4103/ijo.IJO_3030_20.

Abstract

A young lady presented with very high vault and fixed dilated pupil along with optic capture of the implantable collamer lens (ICL). After thorough evaluation and ruling out the ICL sizing error, the optic capture was relieved and the ICL was rotated into vertical position. Single-pass four throw pupilloplasty was performed for the fixed dilated pupil. Postoperatively the ICL vault and the pupil size decreased and patient was asymptomatic. This case highlights a successful outcome of rotation of a nontoric ICL to reduce the high vaulting and optic capture along with single-pass four throw pupilloplasty.

摘要

一位年轻女士出现极高的拱顶和固定性扩大瞳孔,同时伴有可植入Collamer 透镜(ICL)的光学捕获。经过彻底评估并排除 ICL 尺寸错误后,解除了光学捕获,并将 ICL 旋转至垂直位置。对固定性扩大瞳孔进行单次四投瞳孔成形术。术后 ICL 拱顶和瞳孔大小减小,患者无症状。本病例突出了旋转非 toric ICL 以降低高拱顶和光学捕获的成功结果,同时还进行了单次四投瞳孔成形术。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e743/7856946/767eec62e695/IJO-68-3070-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验