Suppr超能文献

Lean-and-Release 测试在不完全性脊髓损伤或疾病患者中的测量性能。

The measurement properties of the Lean-and-Release test in people with incomplete spinal cord injury or disease.

机构信息

Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada.

Lyndhurst Centre, KITE - University Health Network, Toronto, Canada.

出版信息

J Spinal Cord Med. 2022 May;45(3):426-435. doi: 10.1080/10790268.2020.1847562. Epub 2020 Dec 2.

Abstract

OBJECTIVE

To evaluate test-retest reliability, agreement, and convergent validity of the Lean-and-Release test for the assessment of reactive stepping among individuals with incomplete spinal cord injury or disease (iSCI/D).

DESIGN

Multi-center cross-sectional multiple test design.

SETTING

SCI/D rehabilitation hospital and biomechanics laboratory.

PARTICIPANTS

Individuals with motor incomplete SCI/D (iSCI/D).

INTERVENTIONS

None.

OUTCOME MEASURES

Twenty-six participants attended two sessions to complete the Lean-and-Release test and a battery of clinical tests. Behavioral ( one-step, multi-step, loss of balance) and temporal ( timing of foot off, foot contact, swing of reactive step) parameters were measured. Test-retest reliability was determined with intraclass correlation coefficients, and agreement was evaluated with Bland-Altman plots. Convergent validity was assessed through correlations with clinical tests.

RESULTS

The behavioral responses were reliable for the Lean-and-Release test (ICC = 0.76), but foot contact was the only reliable temporal parameter using data from a single site (ICC = 0.79). All variables showed agreement according to the Bland-Altman plots. The behavioral responses correlated with scores of lower extremity strength (0.54, P<0.01) and balance confidence (0.55, P < 0.01). Swing time of reactive stepping correlated with step time (0.73, P < 0.01) and cadence (-0.73 P < 0.01) of over ground walking.

CONCLUSIONS

The behavioral response of the Lean-and-Release test is a reliable and valid measure for people with iSCI/D. Our findings support the use of the behavioral responses to evaluate reactive stepping for research and clinical purposes.

TRIAL REGISTRATION

ClinicalTrials.gov identifier: NCT02960178.

摘要

目的

评估用于评估不完全性脊髓损伤或疾病(iSCI/D)个体反应性迈步的 Lean-and-Release 测试的重测信度、一致性和收敛效度。

设计

多中心横断面多项测试设计。

地点

SCI/D 康复医院和生物力学实验室。

参与者

患有运动性不完全性 SCI/D(iSCI/D)的个体。

干预措施

无。

结果测量

26 名参与者参加了两次会议,以完成 Lean-and-Release 测试和一系列临床测试。测量了行为(一步、多步、失去平衡)和时间(脚离地、脚接触、反应性步的摆动)参数。使用组内相关系数确定重测信度,使用 Bland-Altman 图评估一致性。通过与临床测试的相关性评估收敛效度。

结果

行为反应对 Lean-and-Release 测试具有可靠性(ICC=0.76),但仅在单个部位使用数据时,脚接触是唯一可靠的时间参数(ICC=0.79)。所有变量根据 Bland-Altman 图均显示出一致性。行为反应与下肢力量评分(0.54,P<0.01)和平衡信心评分(0.55,P<0.01)相关。反应性迈步的摆动时间与地面行走的步时(0.73,P<0.01)和步频(-0.73,P<0.01)相关。

结论

Lean-and-Release 测试的行为反应是评估 iSCI/D 人群反应性迈步的可靠和有效的测量方法。我们的研究结果支持使用行为反应来评估反应性迈步,用于研究和临床目的。

试验注册

ClinicalTrials.gov 标识符:NCT02960178。