Suppr超能文献

移植术前含葡聚糖的器官培养液中人供体角膜移植物的厚度和曲率变化。

Thickness and Curvature Changes of Human Corneal Grafts in Dextran-Containing Organ Culture Medium Before Keratoplasty.

机构信息

Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany.

Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany; and.

出版信息

Cornea. 2021 Jun 1;40(6):733-740. doi: 10.1097/ICO.0000000000002543.

Abstract

PURPOSE

To determine the changes of corneal thickness and curvature of human corneal grafts in organ culture medium II, containing dextran T500 6%, before keratoplasty.

METHODS

We examined the tomography of 24 corneas from our eye bank transferred from medium I into medium II. Images were repeated hourly during 24 hours using an anterior segment optical coherence tomography. The central corneal thickness (CCT) was measured with the manual measurement tool of the anterior segment optical coherence tomography. The radii of curvature (anterior flat and steep and posterior flat and steep) were measured with a MATLAB self-programmed software for "sterile donor tomography."

RESULTS

The mean CCT (±SD) at baseline (T0) was 727 ± 156 μm. It reached 581 ± 103, 506 ± 84, 472 ± 79, and 456±7 μm after 6, 12, 18, and 24 hours, respectively. After 12 hours, 83% of the final deswelling was achieved. The radii of curvature (±SD) at baseline (T0) were (posterior flat, posterior steep, anterior flat, and anterior steep) 6.6 ± 0.5, 6.2 ± 0.5, 7.7 ± 0.4, and 7.4 ± 0.4 mm, respectively. After 24 hours, the radii of curvature reached 6.8 ± 0.1, 6.6 ± 0.3, 7.6 ± 0.1, and 7.4 ± 0.2 mm, respectively.

CONCLUSIONS

The kinetics of the deswelling process in medium II follow a hyperbolic curve. Considering a CCT of 506 μm at T12, we assume that a time interval of 12 hours in medium II might be enough for clinical purposes. This result might help to keep storage in medium II as short as possible to escape potential toxic effects of dextran in medium II. The radius of curvature does not seem to change within 24 hours for all measured surfaces.

摘要

目的

在角膜移植术前,确定人供体角膜在含 6%葡聚糖 T500 的器官培养液 II 中的角膜厚度和曲率变化。

方法

我们检查了从我们的眼库转移到培养液 II 中的 24 个供体角膜的断层图。使用眼前节光学相干断层扫描仪(AS-OCT)每小时重复图像一次,持续 24 小时。使用 AS-OCT 的手动测量工具测量中央角膜厚度(CCT)。使用 MATLAB 自行编写的“无菌供体断层扫描”软件测量前、后表面的曲率半径(前平坦和陡峭、后平坦和陡峭)。

结果

基线(T0)时的平均 CCT(±SD)为 727±156μm。分别在 6、12、18 和 24 小时后达到 581±103、506±84、472±79 和 456±7μm。12 小时后,83%的最终肿胀消退。基线(T0)时的曲率半径(±SD)分别为(后平坦、后陡峭、前平坦和前陡峭)6.6±0.5、6.2±0.5、7.7±0.4 和 7.4±0.4mm。24 小时后,曲率半径分别达到 6.8±0.1、6.6±0.3、7.6±0.1 和 7.4±0.2mm。

结论

在培养液 II 中的肿胀消退过程遵循双曲线曲线。考虑到 T12 时的 CCT 为 506μm,我们假设在培养液 II 中 12 小时的时间间隔可能足以满足临床目的。这一结果可能有助于将培养液 II 中的储存时间尽可能缩短,以避免培养液 II 中葡聚糖的潜在毒性作用。在所有测量的表面中,曲率半径似乎在 24 小时内没有变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验