Shacham Maayan, Levin Avi, Shemesh Avi, Lvovsky Alex, Ben Itzhak Joe, Solomonov Michael
Department of Endodontics, Israel Defense Forces (IDF) Medical Corps, Tel Hashomer, Derech Sheba 2, 52621, Ramat Gan, Israel.
BDJ Open. 2020 Nov 17;6(1):22. doi: 10.1038/s41405-020-00052-3.
The aim of the current study was to determine the accuracy of electronic apex locator (EAL) measurements when using files of different sizes in roots with wide apical foramina while considering a new parameter of stability of EAL reading. Ten teeth with straight roots were subjected to a sequential widening of the apical foramen to 0.6, 0.7, and 0.8 mm. The roots were embedded after each enlargement stage in an alginate mold and subjected to EAL readings. Measurements were done using sequential K-file sizes and the self-adjusting file (SAF). Measurement stability was introduced as a new additional parameter. As the difference between the file size used and the apical diameter of the canal decreases, the results obtained were more accurate and stable. The stability and accuracy of the measurements coincided with each other in a statistically significant manner. Within the limitations of the present ex vivo study, it may be concluded that in straight canals with wide apical foramina of 0.6-0.8 mm, both SS K-files which fit snugly to the walls of apical foramen and the SAF file may offer both accurate and stable EAL measurements.
本研究的目的是在考虑电子根尖定位仪(EAL)读数稳定性这一新参数的情况下,确定在根尖孔宽大的牙根中使用不同尺寸锉时EAL测量的准确性。对10颗直根牙的根尖孔依次扩大至0.6、0.7和0.8毫米。在每个扩大阶段后,将牙根嵌入藻酸盐模型中并进行EAL读数。使用连续的K锉尺寸和自调锉(SAF)进行测量。引入测量稳定性作为一个新的附加参数。随着所用锉的尺寸与根管根尖直径之间的差异减小,所获得的结果更准确且稳定。测量的稳定性和准确性在统计学上具有显著的一致性。在本离体研究的局限性范围内,可以得出结论,在根尖孔宽为0.6 - 0.8毫米的直根管中,紧密贴合根尖孔壁的SS K锉和SAF锉都可以提供准确且稳定的EAL测量。