Suppr超能文献

使用Propex Pixi根尖定位仪评估根尖直径与锉针尺寸之间的相关性

Evaluation of Correlation Between apical Diameter and File Size Using Propex Pixi Apex Locator.

作者信息

Kolanu Sreeha Kaluva, Bolla Nagesh, Varri Sujana, Thummu Jayaprakash, Vemuri Sayesh, Mandava Pragna

机构信息

Post Graduate, Master of Dental Surgery in Speciality of Conservative Dentistry & Endodontics, Sibar Institute of Dental Sciences , Guntur, Andhra Pradesh, India .

Head of the Department, Master of Dental Surgery in Speciality of Conservative Dentistry & Endodontics, Sibar Institute of Dental Sciences , Guntur, Andhra Pradesh, India .

出版信息

J Clin Diagn Res. 2014 Dec;8(12):ZC18-20. doi: 10.7860/JCDR/2014/9307.5247. Epub 2014 Dec 5.

Abstract

AIM

AIM of this study is to evaluate the influence of critical diameter of apical foramen and file size using propex pixi apex locator in working length determination.

MATERIALS AND METHODS

In this study, ten single rooted teeth were selected. They were decoronated at cemento enamel junction. After determining the actual working length, they were embedded in alginate mold. Foramina were widened from 0.6mm to 0.8mm. The measurements were taken with electronic apex locator propex pixi with files from sizes 10 K to respective sizes. Statistical accuracy of propex pixi was calculated by using Anova test for different diameters and for the influence of file size.

RESULTS

RESULTS showed that propex pixi apex locator was accurate when foramen diameter is 0.6 (60k file size), its accuracy diminished with increased foramen diameter

CONCLUSION

Propex pixi is accurate for foramen diameter of 0.6mm, independent of file size. Its accuracy decreases as apical foramen widens, so care should be taken when using clinically.

摘要

目的

本研究的目的是评估使用Propex Pixi根尖定位仪时根尖孔临界直径和锉的尺寸对工作长度测定的影响。

材料与方法

本研究选取了10颗单根牙。在牙骨质釉质界处去除牙冠。确定实际工作长度后,将其嵌入藻酸盐模型中。将根尖孔从0.6mm扩大到0.8mm。使用电子根尖定位仪Propex Pixi,用从10 K号到相应尺寸的锉进行测量。通过方差分析计算Propex Pixi对于不同直径以及锉尺寸影响的统计准确性。

结果

结果显示,当根尖孔直径为0.6(60k锉尺寸)时,Propex Pixi根尖定位仪是准确的,其准确性随着根尖孔直径的增加而降低。

结论

Propex Pixi对于0.6mm的根尖孔直径是准确的,与锉的尺寸无关。随着根尖孔变宽,其准确性降低,因此临床使用时应谨慎。

相似文献

1
Evaluation of Correlation Between apical Diameter and File Size Using Propex Pixi Apex Locator.
J Clin Diagn Res. 2014 Dec;8(12):ZC18-20. doi: 10.7860/JCDR/2014/9307.5247. Epub 2014 Dec 5.
2
Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study.
J Endod. 2011 Sep;37(9):1306-9. doi: 10.1016/j.joen.2011.05.007. Epub 2011 Jul 16.
3
In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi.
J Endod. 2020 Feb;46(2):158-161. doi: 10.1016/j.joen.2019.10.035. Epub 2019 Dec 12.
4
An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files.
Restor Dent Endod. 2016 Feb;41(1):6-11. doi: 10.5395/rde.2016.41.1.6. Epub 2016 Jan 4.
5
8
The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures.
Eur Endod J. 2019 Jul 10;4(2):75-79. doi: 10.14744/eej.2019.52724. eCollection 2019.
9
Accuracy of Four Apex Locators in Premolars with Root Resorption: An Study.
Iran Endod J. 2022 Winter;17(1):20-26. doi: 10.22037/iej.v17i1.35498.
10
An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.
Iran Endod J. 2013 Summer;8(3):114-7. Epub 2013 Aug 1.

引用本文的文献

1
Factors influencing the accuracy of electronic apex locators: A scoping review.
Dent Res J (Isfahan). 2025 Jun 27;22:26. doi: 10.4103/drj.drj_634_23. eCollection 2025.
4
The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures.
Eur Endod J. 2019 Jul 10;4(2):75-79. doi: 10.14744/eej.2019.52724. eCollection 2019.

本文引用的文献

1
The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.
J Dent Res Dent Clin Dent Prospects. 2008 Winter;2(1):24-7. doi: 10.5681/joddd.2008.005. Epub 2008 May 15.
2
Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study.
J Endod. 2011 Sep;37(9):1306-9. doi: 10.1016/j.joen.2011.05.007. Epub 2011 Jul 16.
3
Clinical reproducibility of three electronic apex locators.
Int Endod J. 2011 Aug;44(8):769-76. doi: 10.1111/j.1365-2591.2011.01897.x. Epub 2011 May 21.
4
In vitro evaluation of the accuracy of two electronic apex locators.
J Conserv Dent. 2008 Apr;11(2):82-5. doi: 10.4103/0972-0707.44056.
5
Influence of apical constriction diameter on Root ZX apex locator precision.
J Endod. 2007 Aug;33(8):995-8. doi: 10.1016/j.joen.2007.05.009.
6
A comparison between two electronic apex locators: an ex vivo investigation.
Int Endod J. 2007 May;40(5):362-73. doi: 10.1111/j.1365-2591.2006.01229.x. Epub 2007 Feb 19.
7
Evaluation of the accuracy of three electronic apex locators using glass tubules.
Int Endod J. 2006 Feb;39(2):127-35. doi: 10.1111/j.1365-2591.2006.01056.x.
8
Electronic apex locators.
Int Endod J. 2004 Jul;37(7):425-37. doi: 10.1111/j.1365-2591.2004.00835.x.
10
Accuracy of the Endex with variations in canal irrigants and foramen size.
J Endod. 1993 Feb;19(2):63-7. doi: 10.1016/s0099-2399(06)81196-9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验