Suppr超能文献

使用选择离子流动管质谱法同时实时测量树木排放的异戊二烯和2-甲基-3-丁烯-2-醇

Simultaneous Real-Time Measurement of Isoprene and 2-Methyl-3-Buten-2-ol Emissions From Trees Using SIFT-MS.

作者信息

Lehnert Ann-Sophie, Perreca Erica, Gershenzon Jonathan, Pohnert Georg, Trumbore Susan E

机构信息

Department of Biogeochemical Processes, Max Planck Institute for Biogeochemistry, Jena, Germany.

Institute for Inorganic and Analytical Chemistry, Bioorganic Analytics, Friedrich Schiller University, Jena, Germany.

出版信息

Front Plant Sci. 2020 Nov 27;11:578204. doi: 10.3389/fpls.2020.578204. eCollection 2020.

Abstract

The C5 hemiterpenes isoprene and 2-methyl-3-buten-2-ol (MBO) are important biogenic volatiles emitted from terrestrial vegetation. Isoprene is emitted from many plant groups, especially trees such as , while emission of MBO is restricted to certain North American conifers, including species of . MBO is also a pheromone emitted by several conifer bark beetles. Both isoprene and MBO have typically been measured by proton-transfer reaction mass spectrometry (PTR-MS), but this method cannot accurately distinguish between them because of their signal overlap. Our study developed a method for using selective ion flow tube mass spectrometry (SIFT-MS) that allows simultaneous on-line measurement of isoprene and MBO by employing different reagent ions. The use of /(NO) = 68 u for isoprene and /(O ) = 71 u for MBO gave minimal interference between the compounds. We tested the suitability of the method by measuring the emission of young trees of , , and . Our results largely confirm previous findings that , , and emit isoprene and emits MBO, but we also found MBO to be emitted by . Thus SIFT-MS provides a reliable, easy to use, on-line measuring tool to distinguish between isoprene and MBO. The method should be of use to atmospheric chemists, tree physiologists and forest entomologists, among others.

摘要

C5半萜类化合物异戊二烯和2-甲基-3-丁烯-2-醇(MBO)是陆地植被释放的重要生物源挥发性物质。许多植物类群都会释放异戊二烯,尤其是诸如……的树木,而MBO的释放仅限于某些北美针叶树,包括……的物种。MBO也是几种针叶树树皮甲虫释放的一种信息素。异戊二烯和MBO通常都是通过质子转移反应质谱法(PTR-MS)进行测量的,但由于它们的信号重叠,这种方法无法准确区分它们。我们的研究开发了一种使用选择性离子流管质谱法(SIFT-MS)的方法,该方法通过使用不同的反应离子,能够同时在线测量异戊二烯和MBO。使用/(NO)=68 u来测量异戊二烯,使用/(O)=71 u来测量MBO,可使化合物之间的干扰最小。我们通过测量……、……和……幼树的挥发性物质释放来测试该方法的适用性。我们的结果在很大程度上证实了之前的研究发现,即……、……和……释放异戊二烯,……释放MBO,但我们也发现……也会释放MBO。因此,SIFT-MS提供了一种可靠、易于使用的在线测量工具,用于区分异戊二烯和MBO。该方法对大气化学家、树木生理学家和森林昆虫学家等应该会有用处。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/532c/7728719/f0bf4d2d0423/fpls-11-578204-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验