Suppr超能文献

不同体型犬的锁骨下动脉直径和长度与颈外静脉的比较:尸体研究。

Comparison of diameter and length of subclavian arteries to external jugular veins in variably sized dogs: A cadaveric study.

机构信息

Small Animal Clinical Sciences, Veterinary Teaching Hospital, Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia.

Veterinary Clinical Sciences Department, Veterinary Medical Center, University of Minnesota, St. Paul, Minnesota.

出版信息

Vet Surg. 2021 Feb;50(2):418-424. doi: 10.1111/vsu.13555. Epub 2020 Dec 19.

Abstract

OBJECTIVE

To evaluate the length and diameter of a left external jugular vein graft as a substitute for the left subclavian artery in the modified Blalock-Thomas-Taussig shunt (mBTTS) in differently sized dogs.

STUDY DESIGN

Cadaveric study.

ANIMALS

Dog cadavers of three weight categories (10/group): <9.5 kg, 9.5 to 27 kg, and > 27 kg.

METHODS

The length and infused external diameters of harvested vessels were measured with vernier calipers and recorded. A matched-pairs t test was used to test the difference in vessel lengths. The agreement in vessel diameters was assessed by using Lin's concordance correlation coefficient (CCC). Pearson's correlation coefficients (CC) were determined for vessel diameter to weight category and vessel length to weight category.

RESULTS

The external jugular vein measured longer than the subclavian artery in all dogs (52.0 ± 20.8 mm and 23.0 ± 8.9 mm, respectively), with a mean difference of 28 ± 14.3 mm (P < .001). The mean external infused subclavian and external jugular diameters measured 7.8 ± 2.2 mm and 8.0 ± 2.5 mm, respectively (P = .32). Lin's CCC was 0.87. Pearson's CC were 0.74 in both vessel diameters (P < .001); they were 0.36 and 0.43, respectively, for subclavian artery and external juglar vein length (P < .001).

CONCLUSION

Autologous external jugular vein grafts had an external diameter similar to subclavian artery and a significantly longer length in variably sized dogs.

CLINICAL SIGNIFICANCE

External jugular vein grafts may be an acceptable graft choice for mBTTS.

摘要

目的

评估不同大小犬改良 Blalock-Thomas-Taussig 分流术(mBTTS)中左颈外静脉移植物作为左锁骨下动脉替代物的长度和直径。

研究设计

尸体研究。

动物

3 个体重类别(每组 10 只)的犬尸体:<9.5kg、9.5 至 27kg 和>27kg。

方法

用游标卡尺测量并记录收获血管的长度和注入外径。使用配对 t 检验检验血管长度的差异。使用 Lin 的一致性相关系数(CCC)评估血管直径的一致性。确定血管直径与体重类别和血管长度与体重类别的 Pearson 相关系数(CC)。

结果

在所有犬中,颈外静脉的长度均长于锁骨下动脉(分别为 52.0±20.8mm 和 23.0±8.9mm),平均差异为 28±14.3mm(P<0.001)。测量的注入颈外锁骨下和颈外静脉的平均外径分别为 7.8±2.2mm 和 8.0±2.5mm(P=0.32)。Lin 的 CCC 为 0.87。两个血管直径的 Pearson CC 分别为 0.74(P<0.001);锁骨下动脉和颈外静脉长度分别为 0.36 和 0.43(P<0.001)。

结论

自体颈外静脉移植物的外径与锁骨下动脉相似,在不同大小的犬中长度明显更长。

临床意义

颈外静脉移植物可能是 mBTTS 的可接受移植物选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验