STATEMENT OF THE PROBLEM

In an attempt to enhance and simplify the restoration process, a new class of composite resins, called the bulk fill composite resins have been introduced. It is claimed that a depth of cure (DOC) of 4 mm can be achieved without affecting the properties of this material.

PURPOSE

The purpose of this study was to investigate the effect of different shades, thicknesses, and viscosities on the DOC of bulk-fill composites.

MATERIALS AND METHOD

In this experimental study, four bulk-fill composites [Filtek™ Bulk Fill Flowable (FBF), Filtek™ Bulk Fill posterior (FBP), Tetric® N-Flow Bulk Fill (TNF), Tetric® N-Ceram Bulk Fill (TNC)] and a conventional composite, Filtek™ Z250 XT Universal (FZ) were evaluated. The samples (n=5) were made using two different shades (light and dark), thicknesses (2 and 4mm), and viscosities (flowable and sculptable). Microhardness test was conducted on top and bottom surface using Vickers microhardness tester and DOC was calculated as the bottom/top ratio of yielded scores. Statistical analysis was done using a Mann Whitney test at < 0.05.

RESULTS

DOC ranged between 52-95%. FBF composite exhibited the lowest overall hardness numbers. At 2-mm thickness, all the samples achieved an appropriate DOC. However, at 4mm thickness, only the light shades for FBF and TNF samples achieved a DOC very close to 0.8. At 4-mm thickness, the light shades for FBF, TNF and FZ samples exhibited significantly higher DOC compared to dark shades. For 4-mm-thick samples, the DOC of Filtek™ Bulk Fill (dark and light shades (and the DOC of Tetric® Bulk Fill (light shade (were different in flowable type from the sculptable type.

CONCLUSION

The shade and the viscosity of bulk-fill composites influence their DOC at 4-mm depths. Moreover, 20 seconds of light curing appears insufficient for 4mm thickness of bulk-fill composite.

摘要

问题陈述

为了改进和简化修复过程,已引入了一类新型复合树脂,即大块充填复合树脂。据称,该材料可实现4毫米的固化深度(DOC),且不会影响其性能。

目的

本研究的目的是调查不同色度、厚度和粘度对大块充填复合树脂固化深度的影响。

材料与方法

在本实验研究中,评估了四种大块充填复合树脂[Filtek™ 大块充填可流动树脂(FBF)、Filtek™ 大块充填后牙树脂(FBP)、Tetric® N-Flow大块充填树脂(TNF)、Tetric® N-Ceram大块充填树脂(TNC)]以及一种传统复合树脂Filtek™ Z250 XT通用树脂(FZ)。使用两种不同的色度(浅色和深色)、厚度(2毫米和4毫米)和粘度(可流动和可塑形)制作样本(n = 5)。使用维氏显微硬度计在顶面和底面进行显微硬度测试,并将固化深度计算为屈服分数的底面/顶面比率。使用Mann Whitney检验进行统计分析,显著性水平设定为< 0.05。

结果

固化深度在52%至95%之间。FBF复合树脂的总体硬度数值最低。在2毫米厚度时,所有样本均达到了合适的固化深度。然而,在4毫米厚度时,只有FBF和TNF样本的浅色达到了非常接近0.8的固化深度。在4毫米厚度时,与深色相比,FBF、TNF和FZ样本的浅色显示出显著更高的固化深度。对于4毫米厚的样本,Filtek™ 大块充填树脂(深色和浅色)以及Tetric® 大块充填树脂(浅色)的固化深度在可流动型和可塑形型之间存在差异。

结论

大块充填复合树脂的色度和粘度会影响其在4毫米深度的固化深度。此外,对于4毫米厚的大块充填复合树脂,20秒的光固化时间似乎不足。