间质微波天线阵列产生的功率和热量分布:I. 对比模型与犬类研究。

The distribution of power and heat produced by interstitial microwave antenna arrays: I. Comparative phantom and canine studies.

作者信息

Denman D L, Elson H R, Lewis G C, Breneman J C, Clausen C L, Dine J, Aron B S

机构信息

University of Cincinnati School of Medicine, Division of Radiation Oncology, OH 45267-0757.

出版信息

Int J Radiat Oncol Biol Phys. 1988 Jan;14(1):127-37. doi: 10.1016/0360-3016(88)90060-0.

Abstract

To adequately plan and administer localized hyperthermia with interstitial microwave antennas, the thermal distribution patterns generated by such antennas must be characterized. This study evaluated the performance of single node 915 MHz antennas operating either alone or as a 2 cm square array of four parallel antennas using both muscle-equivalent phantoms and canine thigh muscle. Two types of measurements were compared. Specific absorption rate (SAR), where temperature increases resulting from short duration microwave pulses were used to define power distribution, and temperature gradients during simulated hyperthermia treatments. SAR measurements in phantoms were comparable to those obtained in non-perfused canine muscle demonstrating the usefulness of the phantom for these measurements. For a single antenna there was a rapid decrease in power radially which resulted in a steep thermal gradient at distances within 0.5 cm. However, the power generated by a four-antenna array was highest along its central axis and declined to approximately 50% near the antennas at the array periphery. Along the central axis of the array power decreased most rapidly distal to the antenna nodes. The distribution of temperature measured during simulated hyperthermia treatments in phantoms paralleled the SAR distribution and was comparable to the temperature gradient observed in perfused canine muscle, suggesting that phantoms could be used to predict temperature distributions in resting muscle tissue.

摘要

为了充分规划和实施使用间质微波天线的局部热疗,必须对这类天线产生的热分布模式进行表征。本研究使用肌肉等效体模和犬大腿肌肉,评估了单节点915 MHz天线单独工作或作为由四个平行天线组成的2平方厘米阵列工作时的性能。比较了两种测量类型。比吸收率(SAR),即利用短持续时间微波脉冲引起的温度升高来定义功率分布,以及模拟热疗治疗期间的温度梯度。体模中的SAR测量结果与在未灌注犬肌肉中获得的结果相当,证明了体模在这些测量中的有用性。对于单个天线,功率沿径向迅速下降,导致在0.5厘米范围内的距离处出现陡峭的热梯度。然而,四天线阵列产生的功率在其中心轴上最高,在阵列周边的天线附近下降到约50%。在阵列中心轴上,功率在天线节点远端下降最快。在体模模拟热疗治疗期间测量的温度分布与SAR分布平行,并且与在灌注犬肌肉中观察到的温度梯度相当,这表明体模可用于预测静息肌肉组织中的温度分布。

相似文献

5
Evaluation of microwave interstitial antennas in the phantom with varying cross-section.
Int J Radiat Oncol Biol Phys. 1993 Jan;25(1):105-12. doi: 10.1016/0360-3016(93)90151-k.
9
Effect of phase modulation on the temperature distribution of a microwave hyperthermia antenna array in vivo.
Int J Hyperthermia. 1994 Sep-Oct;10(5):691-705. doi: 10.3109/02656739409022448.