• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Laboratory Utilization and Analytical Validation of Fecal Electrolyte Tests.

作者信息

Parakh Rugvedita, Greene Dina N, Mathias Patrick C, Block Darci R, Ranjitkar Pratistha

机构信息

Department of Laboratory Medicine, University of Washington, Seattle, WA.

Department of Pathology, University of Washington, Seattle, WA.

出版信息

J Appl Lab Med. 2017 May 1;1(6):668-677. doi: 10.1373/jalm.2016.022590.

DOI:10.1373/jalm.2016.022590
PMID:33379818
Abstract

BACKGROUND

Chronic diarrhea can be categorized as fatty, watery, or inflammatory. Watery diarrhea is further divided into secretory or osmotic types and can be differentiated by measuring fecal electrolytes and osmotic gap. However, with widespread use of endoscopy, it is unclear if these measurements are being used clinically. Furthermore, because stool is not a validated specimen type for Food and Drug Administration-approved electrolyte assays, utilization is a practical concern for laboratories before analytical validation. Here, we determined the clinical utility and validated the performance characteristics of stool electrolytes on the Beckman Coulter AU680.

METHODS

Historical results and literature review were used to determine the clinically relevant ranges for stool electrolytes (Na+, Cl-, K+, phosphate, and Mg2+). Additionally, medical chart review was performed (n = 44 patients) on results to evaluate their clinical utility in chronic diarrhea work-up. Linearity, precision, and stability studies were performed on the AU680. Accuracy was evaluated by comparing results to the Roche Cobas 6000 c501.

RESULTS

For all cases, stool electrolytes and osmotic gap proved valuable in chronic diarrhea work-up. The imprecision of the assays ranged from 0% to 5.9%. All assays were found to be linear within the instrument's analytical measurement range with appropriate slopes and intercepts. The bias between the AU680 and the Roche c501 ranged from -0.48 to 2.39 (mmol/L or mg/dL). Na+, Cl-, and K+ were stable refrigerated for 5 days and up to 1 freeze-thaw cycle. Phosphate and Mg2+ were stable refrigerated for 48 h, but unstable to freeze-thaw cycles.

CONCLUSIONS

Stool osmotic gap is valuable for evaluating chronic diarrhea and can be calculated using electrolyte concentrations measured on the AU680.

摘要

相似文献

1
Laboratory Utilization and Analytical Validation of Fecal Electrolyte Tests.
J Appl Lab Med. 2017 May 1;1(6):668-677. doi: 10.1373/jalm.2016.022590.
2
Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.用于评估不明原因腹泻的粪便电解质检测:在缺乏参考方法的情况下验证体液检测准确性
Clin Biochem. 2015 Nov;48(16-17):1126-30. doi: 10.1016/j.clinbiochem.2015.06.011. Epub 2015 Jun 17.
3
Filling in the gaps with non-standard body fluids.用非标准体液填补缺口。
Pract Lab Med. 2016 Mar 16;5:24-31. doi: 10.1016/j.plabm.2016.03.003. eCollection 2016 Aug 1.
4
The fecal osmotic gap: technical aspects regarding its calculation.粪便渗透间隙:关于其计算的技术要点。
J Lab Clin Med. 1992 Apr;119(4):359-63.
5
Method Performance of Bicarbonate and Electrolytes by Use of Duodenal Fluid for Assessment of Exocrine Pancreatic Function.使用十二指肠液评估外分泌胰腺功能时碳酸氢盐和电解质的方法性能
J Appl Lab Med. 2018 Jul 1;3(1):56-64. doi: 10.1373/jalm.2017.024695.
6
Stool electrolyte and osmolality measurements in the evaluation of diarrheal disorders.粪便电解质和渗透压测量在腹泻性疾病评估中的应用
Ann Intern Med. 1985 Jun;102(6):773-5. doi: 10.7326/0003-4819-102-6-773.
7
Clinical and laboratory approaches to evaluate diarrheal disorders.评估腹泻性疾病的临床和实验室方法。
Crit Rev Clin Lab Sci. 1987;25(1):43-69. doi: 10.3109/10408368709105877.
8
Mechanism of diarrhea in microscopic colitis.显微镜下结肠炎的腹泻机制。
World J Gastroenterol. 2005 Sep 21;11(35):5535-9. doi: 10.3748/wjg.v11.i35.5535.
9
10
The effect of sodium bicarbonate and validation of beckman coulter AU680 analyzers for measuring total carbon dioxide (TCO) concentrations in horse serum.碳酸氢钠的作用以及贝克曼库尔特AU680分析仪用于测量马血清中总二氧化碳(TCO)浓度的验证。
Vet Med Sci. 2017 Oct 25;3(4):263-269. doi: 10.1002/vms3.82. eCollection 2017 Nov.

引用本文的文献

1
New Faecal Calprotectin Assay by IDS: Validation and Comparison to DiaSorin Method.IDS公司新型粪便钙卫蛋白检测法:验证及与DiaSorin方法的比较
Diagnostics (Basel). 2022 Sep 27;12(10):2338. doi: 10.3390/diagnostics12102338.