Department of Ophthalmology, Vita-Salute University, IRCCS Ospedale San Raffaele Scientific Institute, Via Olgettina, 60 20132, Milan, Italy.
Int Ophthalmol. 2021 Mar;41(3):1033-1041. doi: 10.1007/s10792-020-01660-6. Epub 2021 Jan 3.
To compare two commercially available staining solutions (MembraneBlue Dual® by D.O.R.C., Netherlands, and TWIN by AL.CHI.MI.A. S.R.L., Italy), in terms of intraoperative handling, staining efficacy and safety, in eyes undergoing surgery for idiopathic epiretinal membrane (ERM).
In this observational cross-sectional study, the performance of the dyes used during the procedure (cohesion, ERM and internal limiting membrane [ILM] staining efficacy) was scored by the surgeon using a customized questionnaire after 10 procedures with each of the two dyes. Best-corrected visual acuity (BCVA), central foveal thickness (CFT), blue-light fundus autofluorescence (BAF), and microperimetry-determined retinal sensitivity were reviewed preoperatively and then at 1 and 3 months after surgery.
ILM staining efficacy with TWIN was scored 2.89 ± 0.33 by the surgeons, which turned out to be higher than with MembraneBlue Dual® (1.90 ± 0.31, P = 0.0002). The cohesion score was 2.70 ± 0.48 for TWIN and resulted significantly higher than with MembraneBlue Dual® (1.60 ± 0.51, P = 0.0010). BCVA, CFT and retinal sensitivity were similar in the two groups, 1 and 3 months postoperatively (P nonsignificant for all).
Both TWIN and MembraneBlue Dual® dyes showed suitable staining properties and equivalent safety and efficacy profiles, both intra- and postoperatively. The TWIN dye might offer a solution for surgeons who prefer a more cohesive and stable dye.
比较两种市售染色液(荷兰 D.O.R.C. 公司的 MembraneBlue Dual®和意大利 AL.CHI.MI.A. S.R.L. 公司的 TWIN)在特发性视网膜内界膜(ERM)手术中术中操作、染色效果和安全性方面的差异。
在这项观察性横断面研究中,在 10 例手术中分别使用这两种染色液,由外科医生使用定制的问卷对手术过程中染色剂的性能(黏附性、ERM 和内界膜 [ILM] 染色效果)进行评分。分别在术前和术后 1 个月和 3 个月评估最佳矫正视力(BCVA)、中心视网膜厚度(CFT)、蓝光眼底自发荧光(BAF)和微视野视网膜敏感性。
外科医生对 TWIN 的 ILM 染色效果评分 2.89±0.33,明显高于 MembraneBlue Dual®(1.90±0.31,P=0.0002)。TWIN 的黏附性评分为 2.70±0.48,明显高于 MembraneBlue Dual®(1.60±0.51,P=0.0010)。术后 1 个月和 3 个月,两组间 BCVA、CFT 和视网膜敏感性相似(P 均无统计学意义)。
TWIN 和 MembraneBlue Dual®两种染色剂均显示出合适的染色特性和等效的安全性及疗效,术中及术后均如此。TWIN 染色剂可能为喜欢更黏附、更稳定染色剂的外科医生提供了一种选择。