Wetherbee J N, Bamrah V S, Ptacin M J, Kalbfleisch J H
Medical College of Wisconsin, Milwaukee.
J Am Coll Cardiol. 1988 Feb;11(2):330-7. doi: 10.1016/0735-1097(88)90098-8.
Significant differences in the hemodynamic response to upright and supine exercise have been reported in patients with coronary artery disease. The purpose of the present study was to compare the degree of myocardial ischemia as assessed by ST segment depression during upright treadmill and supine bicycle exercise in 98 patients with coronary artery disease and in 34 patients with normal coronary arteries. The amount of ST segment depression at maximal exercise in patients with coronary artery disease was 0.90 +/- 0.80 mm for treadmill and 1.34 +/- 1.09 mm for supine bicycle (p less than 0.001). The amount of ST segment depression during treadmill and supine bicycle exercise tests was also compared at highest similar heart rates (0.68 +/- 0.77 versus 1.17 +/- 1.01, p less than 0.001), at highest similar rate-pressure products (0.71 +/- 0.77 versus 1.08 +/- 1.04, p less than 0.001), at highest similar metabolic equivalents of oxygen consumption (MET) levels (0.69 +/- 0.75 versus 1.20 +/- 1.05 mm, p less than 0.001) and at the onset of angina (0.84 +/- 0.73 versus 1.18 +/- 0.88 mm, p less than 0.001). The rate-pressure product achieved at maximal exercise was similar in both tests (18.74 +/- 5.80 x 10(3) versus 18.81 +/- 5.17 x 10(3), p = NS). The occurrence of angina during treadmill and supine bicycle exercise tests was similar (47 of 98 versus 48 of 98, respectively, p = NS). For the detection of coronary artery disease, the sensitivity was 50.0% for treadmill and 63.3% for supine bicycle (p less than 0.05) and the specificity was 73.5 versus 70.6%, respectively (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)
据报道,冠状动脉疾病患者对直立运动和仰卧运动的血流动力学反应存在显著差异。本研究的目的是比较98例冠状动脉疾病患者和34例冠状动脉正常患者在直立跑步机运动和仰卧自行车运动期间通过ST段压低评估的心肌缺血程度。冠状动脉疾病患者在最大运动时跑步机运动的ST段压低量为0.90±0.80毫米,仰卧自行车运动为1.34±1.09毫米(p<0.001)。还比较了跑步机运动和仰卧自行车运动试验在最高相似心率时(0.68±0.77对1.17±1.01,p<0.001)、最高相似速率-压力乘积时(0.71±0.77对1.08±1.04,p<0.001)、最高相似氧耗代谢当量(MET)水平时(0.69±0.75对1.20±1.05毫米,p<0.001)以及心绞痛发作时(0.84±0.73对1.18±0.88毫米,p<0.001)的ST段压低量。两种试验在最大运动时达到的速率-压力乘积相似(18.74±5.80×10³对18.81±5.17×10³,p=无显著差异)。跑步机运动和仰卧自行车运动试验期间心绞痛的发生率相似(分别为98例中的47例和98例中的48例,p=无显著差异)。对于冠状动脉疾病的检测,跑步机运动的敏感性为50.0%,仰卧自行车运动为63.3%(p<0.05),特异性分别为73.5%和70.6%(p=无显著差异)。(摘要截短于250字)