Arslan Hakan, Doğanay Yıldız Ezgi, Taş Gizem, Karataş Ertuğrul, Tepecik Ebru
Department of Endodontics, Faculty of Dentistry, Health Sciences University, İstanbul, Turkey.
Department of Endodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey.
J Dent Res Dent Clin Dent Prospects. 2020 Summer;14(3):153-157. doi: 10.34172/joddd.2020.038. Epub 2020 Sep 21.
The present study aimed to evaluate the impact of continuous irrigation with saline solution at room temperature or +4°C on the cyclic fatigue resistance of K3XF files. Forty-eight new K3XF files (#30, .04 taper) were randomly assigned to three groups: control group (no irrigation), continuous irrigation with saline solution at room temperature, and continuous irrigation with saline solution at +4°C. The instruments were tested in an artificial, stainless steel root canal with a double curvature at body temperature (37±1°C). Time to fracture was converted to the number of cycles to fracture (NCF). The lengths of the fractured fragments were recorded. Kruskal-Wallis H test and one-way ANOVA were used to analyze data. K3XF files' cyclic fatigue resistance was significantly higher in the continuous irrigation groups than in the control group. Continuous irrigation with saline solution at +4°C resulted in higher cyclic fatigue resistance than continuous irrigation with saline solution at room temperature. There were no significant differences between the groups in terms of the fractured fragments' length. Within this study's limitations, continuous irrigation with saline solution increased the NCF of NiTi instruments; decreasing the saline solution's temperature increased this effect.
本研究旨在评估室温或 +4°C 的盐溶液持续冲洗对 K3XF 锉抗循环疲劳性能的影响。将 48 支新的 K3XF 锉(#30,0.04 锥度)随机分为三组:对照组(不冲洗)、室温下用盐溶液持续冲洗组和 +4°C 下用盐溶液持续冲洗组。器械在体温(37±1°C)下的人工不锈钢双弯根管中进行测试。将断裂时间转换为断裂循环次数(NCF)。记录断裂碎片的长度。采用 Kruskal-Wallis H 检验和单因素方差分析进行数据分析。持续冲洗组中 K3XF 锉的抗循环疲劳性能显著高于对照组。与室温下用盐溶液持续冲洗相比,+4°C 下用盐溶液持续冲洗导致更高的抗循环疲劳性能。各组之间在断裂碎片长度方面无显著差异。在本研究的局限性范围内,盐溶液持续冲洗增加了镍钛器械的 NCF;降低盐溶液温度增强了这种效果。