Uslu Gülşah, Özyürek Taha, Gündoğar Mustafa, Yılmaz Koray
Department of Endodontics, Faculty of Dentistry, Çanakkale Onkekiz Mart University, Çanakkale, Turkey.
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.
J Dent Res Dent Clin Dent Prospects. 2018 Fall;12(4):283-287. doi: 10.15171/joddd.2018.044. Epub 2018 Dec 19.
The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.
本研究的目的是比较2Shape、Twisted File(TF)和EndoSequence Xpress(ESX)镍钛旋转锉在根管内温度(35°C)下的抗循环疲劳性能。对20支2Shape TS1(25/.04)、20支TF(25/.04)和20支ESX(25/.04)锉在根管内温度(35°C)下进行循环疲劳测试。所有器械均在由不锈钢制成的人工根管中旋转,该根管内径为1.5 mm,弯曲角度为60°,曲率半径为5 mm,直至器械折断;使用数字计时器以秒为单位记录折断时间,并计算每支锉的折断循环次数(NCF)。使用SPSS 21.0进行Kruskal-Wallis检验并采用Bonferroni校正对数据进行统计学分析。设定统计学显著性水平为P<0.05。NCF值显示,在根管内温度下,2Shape的抗循环疲劳性能显著最高,其次是TF和ESX(P<0.05)。TF组和ESX组之间的差异具有显著性(P<0.05)。2Shape、TF和ESX锉在折断锉片段的长度方面无显著差异(P>0.05)。在本研究的局限性范围内,得出结论:在根管内温度下,2Shape锉的抗循环疲劳性能高于TF和ESX锉。