Suppr超能文献

尿道造影检查:患者及工作人员的照射剂量与相关放射生物学风险。

Urethrographic examinations: Patient and staff exposures and associated radiobiological risks.

作者信息

Alkhorayef M, Sulieman A, Barakat H, Al-Mohammed H I, Theodorou K, Kappas C, Bradley D

机构信息

Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia.

Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O. Box 422, Alkharj 11942, Saudi Arabia.

出版信息

Saudi J Biol Sci. 2021 Jan;28(1):35-39. doi: 10.1016/j.sjbs.2020.08.026. Epub 2020 Aug 25.

Abstract

Medical exposure of the general population due to radiological investigations is the foremost source of all artificial ionising radiation. Here, we focus on a particular diagnostic radiological procedure, as only limited data are published with regard to radiation measurements during urethrograpic imaging. Specifically, this work seeks to estimate patient and occupational effective doses during urethrographic procedures at three radiology hospitals. Both staff and patient X-ray exposure levels were calculated in terms of entrance surface air kerma (ESAK), obtained by means of lithium fluoride thermoluminescent dosimeters (TLD-100(LiF:Mg:Cu.P)) for 243 urethrographic examinations. Patient radiation effective doses per procedure were estimated using conversion factors obtained from the use of Public Health England computer software. In units of mGy, the median and range of ESAK per examination were found to be 10.8 (3.6-26.2), 7.0 (0.2-32.3), and 24.3 (9.0-32.0) in Hospitals A, B, and C, respectively. The overall mean and range of staff doses (in µGy) were found to be 310 (4.0-1750) per procedure. With the exception of hospital C, the present evaluations of radiation dose have been found to be similar to those of previously published research. The wide range of patient and staff doses illustrate the need for radiation dose optimisation.

摘要

由于放射学检查导致的普通人群的医疗照射是所有人工电离辐射的首要来源。在此,我们聚焦于一种特定的诊断性放射学检查程序,因为关于尿道造影成像期间的辐射测量仅有有限的数据发表。具体而言,这项工作旨在估算三家放射医院在尿道造影检查过程中患者和职业人员的有效剂量。通过使用氟化锂热释光剂量计(TLD - 100(LiF:Mg:Cu.P))对243例尿道造影检查获取入口表面空气比释动能(ESAK),据此计算工作人员和患者的X射线照射水平。每次检查的患者辐射有效剂量使用从英国公共卫生计算机软件获得的转换因子进行估算。在医院A、B和C中,每次检查的ESAK的中位数和范围分别以毫戈瑞为单位,依次为10.8(3.6 - 26.2)、7.0(0.2 - 32.3)和24.3(9.0 - 32.0)。工作人员剂量(以微戈瑞为单位)的总体平均值和范围为每次检查310(4.0 - 1750)。除了医院C,目前对辐射剂量的评估已发现与先前发表的研究结果相似。患者和工作人员剂量的广泛范围表明了优化辐射剂量的必要性。