Suppr超能文献

评估 2 型糖尿病患者和健康对照者心肌微血管功能的时间变化:无创性方法。

Non-invasive assessment of temporal changes in myocardial microvascular function in persons with type 2 diabetes and healthy controls.

机构信息

Steno Diabetes Center Copenhagen, Copenhagen, Denmark.

Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet, Denmark.

出版信息

Diabet Med. 2021 Jun;38(6):e14517. doi: 10.1111/dme.14517. Epub 2021 Jan 25.

Abstract

BACKGROUND

Cardiac Rubidium-82 ( Rb) positron emission tomography/computed tomography (PET/CT) provides a measure of the myocardial blood flow and the myocardial flow reserve, which reflects the function of both large epicardial arteries and the myocardial microcirculation. Knowledge on changes in the myocardial microvascular function over time is lacking.

METHODS

In this cohort study, we recruited 60 persons with type 2 diabetes and 30 non-diabetic controls, in 2013; all free of overt cardiovascular disease. All underwent a cardiac Rb PET/CT scan. In 2019, all survivors (n = 82) were invited for a repeated cardiac Rb PET/CT scan using the same protocol, and 29 with type 2 diabetes and 19 controls participated.

RESULTS

Median duration between visits was 6.2 years (IQR: 6.1-6.3). In the total cohort, the mean age was 66.4 years (SD: 9.3) and 33% were females. The myocardial flow reserve was lower in persons with type 2 diabetes compared to controls (p = 0.002) but there was no temporal change in the myocardial flow reserve in participants with type 2 diabetes: mean change: -0.22 (95% CI: -0.47 to 0.02) nor in controls: -0.12 (-0.49 to 0.25) or when comparing type 2 diabetes to controls: mean difference: -0.10 (95% CI: -0.52 to 0.31). The temporal reduction in stress-induced myocardial blood flow did not differ within the groups but was more pronounced in type 2 diabetes compared to controls: mean difference: -0.30 (95% CI: -0.55 to -0.04).

CONCLUSION

The myocardial microvascular function was impaired in persons with type 2 diabetes compared to controls but did not change significantly in either of the groups when evaluated over 6 years.

摘要

背景

心脏放射性铷-82(Rb)正电子发射断层扫描/计算机断层扫描(PET/CT)提供了心肌血流和心肌血流储备的测量值,反映了大的心外膜动脉和心肌微循环的功能。目前缺乏关于心肌微血管功能随时间变化的知识。

方法

在这项队列研究中,我们于 2013 年招募了 60 名 2 型糖尿病患者和 30 名非糖尿病对照者,均无明显心血管疾病。所有患者均接受了心脏 Rb PET/CT 扫描。2019 年,所有幸存者(n=82)均按照相同方案接受了重复的心脏 Rb PET/CT 扫描,其中 29 名患有 2 型糖尿病,19 名患有对照组。

结果

两次就诊之间的中位时间为 6.2 年(IQR:6.1-6.3)。在总队列中,平均年龄为 66.4 岁(SD:9.3),33%为女性。与对照组相比,2 型糖尿病患者的心肌血流储备较低(p=0.002),但 2 型糖尿病患者的心肌血流储备没有随时间发生变化:平均变化量为-0.22(95%CI:-0.47 至 0.02),对照组为-0.12(-0.49 至 0.25),或 2 型糖尿病与对照组相比:平均差值为-0.10(95%CI:-0.52 至 0.31)。各组内的应激诱导心肌血流减少无明显差异,但与对照组相比,2 型糖尿病患者更为明显:平均差值为-0.30(95%CI:-0.55 至 -0.04)。

结论

与对照组相比,2 型糖尿病患者的心肌微血管功能受损,但在 6 年的随访中,两组患者的心肌微血管功能均无明显变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4112/8248340/6a03cc32efa2/DME-38-0-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验